System ON

 - The Forté A-BUS system will activate if any function button is 

pressed. 

Input Selection [1]

 - The system will restart on the last source selected. One 

of the four input LEDs [5] will indicate which input has been selected. The 
input can be changed by pressing left or right buttons [1]. 

Volume Level [2]

 - If the system is muted the VCM will restart at low volume 

level. If the system has remained active the VCM 
will return to the previously selected volume level. 
The level may be adjusted by pressing the Up/Down 
buttons [2]. While the level is being adjusted, the input 
LEDs [5] will ripple left or right. 

Remote Control [4]

 - The VCM may be operated 

by remote control. The IR remote must have clear 
line-of-site to the IR Receiver. The VCM can also 
relay IR remote control commands to the hub and 
connected source components. It will repeat standard 
38 kHz commands and 56 kHz commands which are 
often used in satellite receivers. You may experience 
difficulty with some remote control commands on 
some components. The operating range can be 
affected by sunlight and some lighting systems.

Mute and Global Mute [3]

 - A VCM can be muted 

individually by pressing the mute button, this will turn 
off the backlighting to the volume control [2] and input 
selection buttons [1]. The backlighting of the mute [3] 
and input indicator will [5] remain on. If there are other 
VCM’s connected to the same zone their status will 

not be affected. If the mute button [3] is pressed for more than three seconds 
the whole Forté A-BUS system will turn mute. When the system is muted the 
infrared relay will remain active. 

Backlight adjustment [6]

 - The backlighting level of the function buttons [1] 

[2] [3] can be adjusted to individual requirements.

42mm

BACK

AB-40RC

FRONT

70.25mm

106mm

42.75mm

71mm

L-     L+

R+     R-

SPEAKER OUT

LEVEL ADJUST

L CH      R CH

l

2

3

ABO-40RC

4

Size with faceplate: 75 x 116 x 55mm (WHD)

Features and Specifications

AB-20 VCM

Control Rotary Volume
Terminals  

 Input: Cat5 
RJ45 T568A

 

Output: screw 
terminal  (up to 14 gauge)

Infrared Repeating   None
Status 

None

Size with faceplate   75mm x 116mm x 47mm 

(WHD)

AB-39/AB-43 VCM

Infrared Repeating    38KHz and 56KHz
Nominal IR Range    In sunlight < 5M, 

 

Indoors > 20M

Status  

 (System ON)

 

Indicated by red LED

Infrared Talkback  

LED Flashes when in use

Terminals 

Cat5 RJ45 T568A

Size with faceplate   75mm x 116mm x 47mm 

(WHD)

AB-43 VCM 

Same as AB-39 with

 

•  Touch and hold for Up/Down volume
• Touch (down button) is mute
•  Touch (up button) deactivates mute and 

resumes same volume level

•  Remote controllable volume level
• Credit card remote supplied

AB-45 Multi-source VCM 

Control 

 Touch button and remote 
volume control “Local On 
/ Mute, Global Mute” and 
“Source Select” buttons

IR LED 

Repeating with confirmation

Status LED  Muting facility with indicator

 

 

(centre button)

Input 

RJ-45 T568A 

Output 

screw terminal (up to 14 gauge)

Size -profile  13mm, mounting depth: 55mm
Plate Size 

75 x 116 mm (WH)

Credit card remote supplied

AB-70 LIM

•  Auto switching when local audio signal is 

sensed.

•  Auto return 30 seconds after audio 

ceases

Inputs  

 Local Audio - RCA Phono 
jacks (1pr.)

 

From hub - RJ-45 T568A

Output   To Volume Control - RJ-45 T568A

Size with faceplate  

 

 

25mm x 107mm x 44mm (WHD)

Control Functions [1] [2] [3]

Warranty

Please contact your place of purchase for warranty information. 

A-BUS is a registered trademark of LeisureTech Electronics. The A-BUS technology is covered by the following patents - United States US 
7,181,023, 7,668,318 , 6,389,139; Australia AU 739808; New Zealand NZ 502982; Mexico MX 241196; Canada CA 2301062.  

 

All features and specifications are subject to change without notice  www.leisuretech.com.au

This Keypad Volume Control Module (VCM) has been 
designed to work with Forté A-BUS Multi-Source Hubs using 
standard A-BUS commands. It will operate with other single-
source and multi-source hubs; however, some functionality 
such as source selection will not be required. 

These functions can be accessed with an A-BUS remote control handset 
containing the correct codes. 

Note:

 For comprehensive instructions please also refer to the instructions 

supplied with your Forté A-BUS multi-source hub.

Volume Control Module AB-45 Multi-Source