Data : 01.03.2016
5
Operation
5.1
Digital Operator Terminal
The integrated digital operator terminal (DBE) with LED
display and three–button keypad
(Figur 1, items 1 to
4)
is used for operating the unit and reading operating
parameters. The unit is normally in the power down
mode. This is indicated on the display
(4)
by a horizon-
tal bar running from left to right.
–
If the unit detects a lift signal (E6), the display show
steps running from
bottom
left to
top
right.
–
–
–
In the case of a lower signal (E2,) the steps run from
top
left to
bottom
right.
–
–
–
Following each operation of the hoist, the current rea-
ding of the operating hours meter is shown on the dis-
play for about 3 seconds.
The parameter level consists of three operation levels.
In order to access level 3, a PIN authorized by ABUS
and a special CODE no. must be entered.
Menu level 2 is accessed by entering the PIN number
“0055”.
Menu level 1 us used solely for reading the values of the
load population recorder and is only available if the load
population recorder has been enabled. To reach this
menu level, press the ENTER button for about 2 se-
conds and then enter the appropriate CODE number
(see Section 5.3)
If four incorrect attempts are made to enter a PIN or
CODE number, the menu level concerned is entirely di-
sabled and can only be enabled by ABUS.
In this case,
[no]
appears on the display.
95
100
100
75
5
1
2
4
3
1 “Enter”–key
2 “up“–key
3 “down”–key
4 Display
5 digital operator terminal (DBE)
Height: 112
Figur 1
5.2
Basic Settings
TheLIS–SE is adjusted at the factory. Any fine adjust-
ments or new adjustments which may be necessary
can be carried out in accordance with the adjustment
instructions in chapter 10 using a test load. Where pos-
sible, the test load should be equal to the rated load.
If the test load is lower, there will be a significant deterio-
ration in system accuracy. As a basic principle, the hig-
her the test load, the higher the accuracy. It is recom-
mended that a test load of at least 80 % of the rated load
should be used.
5.3
Reading the Load Population
Recorder
Menu level 1
The work required for enabling the load population re-
corder can only be performed by ABUS.
If a valid code number “2223” is entered, the values sto-
red and calculated by the load population recorder are
displayed in sequence. To return to level 1, you must
press the enter button (1,
Figur 1
) for a little longer.