User Operation Guide
** For detail, updated Command Code and Application Software, please visit and download from
www.abtussingapore.com
PRODUCT HIGHLIGHTS
•
Multi-Stage surge protection
•
Linear Filtering Technology
•
Front panel power status LEDs
•
External I/Os allow remote operation
** For detail, updated Command Code and Application Software, please visit and download from
www.abtussingapore.com
Item
Description
1. POWER
Main Power ON/OFF switch
2. CIRCUIT BREAKER
Max overall load capacity is 10 amp, this circuit breaker will trip should the combined
current drawn by all connected equipments exceed 10 amp.
Should this occurs, reduce the load so that they are within the range.
Reset can be done by simply pressing the reset button, however, please note that this is a
thermal trip supplementary protector. (*Cooling time is required before reset is allow)
3. SWTCHED AC OUTLET
Provide a power outlet from front panel with main power ON/OFF and when the system
is in and under normal power condition.
4. PROTECTION OK
LED is at solid green when system is under normal condition.
LED goes OFF when a extreme large surge occurs, all relays will open.
5. EXTREME VOLTAGE
LED is normally off, it will only turn solid red when unit received voltage that is out of
the range below (185VAC) or above (265VAC)
*System will only allow reset (OFF/ON main power switch) when the incoming voltage
is back within the safety range.
6. SEQUENCE START
Push to reset and begin an ON sequence
7. DELAY STATUS
LEDs, each LED provide the relay/delay status of the corresponding port.
8. SEQUENCE ON/OFF
ON/OFF of a sequence which allow outlets to be turn on one at a time with a delay time
(Variable and programmable) between each one.
9. LAMP ON/OFF
ON/OFF control for rear 12VDC (500mA) supply which allow any gooseneck lamp/LED
to be connected.
Front Panel View
1
2
3
4
5
6
7
8
9
•
8 switched outlets (rear) and one pass through
un-switched outlet (front)
•
12VDC supply (BNC) allow any gooseneck lamp or LEDs
that provides a cool running source for the rack
1
2
3
4
Item
Description
1. LAMP
BNC 12VDC (500mA) gooseneck lamp/LED
2. LED - START SEQ- GND
External control and status for Start Sequence
3. DELAY 1 to DELAY 8
AC outlet with delays and sequence based on programmed timing (1~60 Sec)
4. AC AC220~240 50/60Hz
AC Input socket, AC220~240 50/60Hz
Communication Parameter
RS-232 Command Code
Description
Setting
Baud Rate :
9600bps
Data Length : 8 bits
Parity :
Non Parity
Stop Bit :
One stop bit
X On/Off :
None
RS-232 connection
Pin
Function
1 Tx
Transmit data
2 Rx
Receive data
3 GND
Ground
Tx - Rx - GND
Item
Description
Command code (Hex)
1.
Enter Setting Mode
Send
53 45 54 53 07 50 57 52 44 41 30 39 43
Return
52 45 54 53 07 50 57 52 44 41 30 39 43
2.
Set Relay 01 ON (Hex 01) Delay 01 sec
Send
53 45 54 53 04 44 4C 01 01
Return
52 45 54 53 04 44 4C 01 01
3.
Set Relay 02 ON (Hex 02) Delay 02 sec
Send
53 45 54 53 04 44 4C 02 02
Return
52 45 54 53 04 44 4C 02 02
4.
Set Relay 03 ON (Hex 03) Delay 03 sec
Send
53 45 54 53 04 44 4C 03 03
Return
52 45 54 53 04 44 4C 03 03
5.
Set Relay 04 ON (Hex 04) Delay 04 sec
Send
53 45 54 53 04 44 4C 04 04
Return
52 45 54 53 04 44 4C 04 04
6.
Set Relay 05 ON (Hex 05) Delay 05 sec
Send
53 45 54 53 04 44 4C 05 05
Return
52 45 54 53 04 44 4C 05 05
7.
Set Relay 06 ON (Hex 06) Delay 06 sec
Send
53 45 54 53 04 44 4C 06 06
Return
52 45 54 53 04 44 4C 06 06
8.
Set Relay 07 ON (Hex 07) Delay 07 sec
Send
53 45 54 53 04 44 4C 07 07
Return
52 45 54 53 04 44 4C 07 07
9.
Set Relay 08 ON (Hex 08) Delay 08 sec
Send
53 45 54 53 04 44 4C 08 08
Return
52 45 54 53 04 44 4C 08 08
10.
Set Relay 08 ON (Hex 08) Delay 10 sec (Hex 0A)
Send
53 45 54 53 04 44 4C 08 0A
Return
52 45 54 53 04 44 4C 08 0A
11.
Set Relay 08 OFF (Hex 10) Delay 01 sec
Send
53 45 54 53 04 44 4C 10 01
Return
52 45 54 53 04 44 4C 10 01
12.
Set Relay 07 OFF (Hex 0F) Delay 02 sec
Send
53 45 54 53 04 44 4C 0F 02
Return
52 45 54 53 04 44 4C 0F 02
13.
Set Relay 06 OFF (Hex 0E) Delay 03 sec
Send
53 45 54 53 04 44 4C 0E 03
Return
52 45 54 53 04 44 4C 0E 03
14.
Set Relay 05 OFF (Hex 0D) Delay 04 sec
Send
53 45 54 53 04 44 4C 0D 04
Return
52 45 54 53 04 44 4C 0D 04
15.
Set Relay 04 OFF (Hex 0C) Delay 05 sec
Send
53 45 54 53 04 44 4C 0C 05
Return
52 45 54 53 04 44 4C 0C 05
16.
Set Relay 03 OFF (Hex 0B) Delay 06 sec
Send
53 45 54 53 04 44 4C 0B 06
Return
52 45 54 53 04 44 4C 0B 06
17.
Set Relay 02 OFF (Hex 0A) Delay 07 sec
Send
53 45 54 53 04 44 4C 0A 07
Return
52 45 54 53 04 44 4C 0A 07
18.
Set Relay 01 OFF (Hex 09) Delay 08 sec
Send
53 45 54 53 04 44 4C 09 08
Return
52 45 54 53 04 44 4C 09 08
19.
Set Relay 01 OFF (Hex 09) Delay 10 sec (Hex 0A)
Send
53 45 54 53 04 44 4C 09 0A
Return
52 45 54 53 04 44 4C 09 0A
20.
Exit (Setting Mode)
Send
53 45 54 53 06 49 53 50 4F 4B 21
Return
53 45 54 53 06 49 53 50 4F 4B 21
Back Panel View