STR1 Roadway Lantern 

ABT 15ATEX4111 

Installation, Operation and Maintenance Instructions 

 

Description 

The Abtech STR1 range of roadway lanterns are manufactured in Aluminium with a toughened glass 

window and silicone rubber gaskets providing sealing. The type of protection is Ex ec, Increased 

Safety.  

 

Application 

The luminaire is suitable for use in a Zone 2 area, gas and dust hazards, and reference should be 

made to the rating table below in respect of T rating and ambient temperature considerations. 

The luminaire is designed for use in areas not subject to levels of vibration or shock above those 

considered normal for fixed installations. Care should be taken, not to expose the gasket(s) to high 

concentrations of hydrocarbon vapours. 

‘This equipment uses an external non-metallic coating. To avoid the build-up of an electrostatic 

charge clean only with a damp cloth.’ 

Refer to apparatus certificates (supplied with luminaire and available at www.abtech.eu) for details 

of certification, coding, conditions for safe use. 

 

Refer to apparatus label for warnings 

 
 
 

Product 

Reference 

Colour 

Temperature (K) 

Ambient Temp  Power 

(W) 

Temp Class and Surface Temp 

Weight 

(kg) 

LX2STR1120SH 

4000 

-50°C to +55°C

 

120 

T4 

 

T135

o

 

11 

 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

Product Reference 

Lamp  

Power 

LED  

Current 

Input Voltage 

Input Frequency 

Power factor 

Correction 

 

LX2STR1120SH 

 

120W 

0.7A 

90 to 305 Vac 

50Hz to 60Hz 

>0.95 

Luminaire Ratings

 

Operating Parameters

 

Содержание STR1 Series

Страница 1: ...s designed for use in areas not subject to levels of vibration or shock above those considered normal for fixed installations Care should be taken not to expose the gasket s to high concentrations of hydrocarbon vapours This equipment uses an external non metallic coating To avoid the build up of an electrostatic charge clean only with a damp cloth Refer to apparatus certificates supplied with lum...

Страница 2: ...should be pole mounted which is not prone to excessive levels of vibration or shock No objects should be placed within 1m directly in front of the glass window The luminaire should be fixed in position in accordance with lighting design parameters and secured using appropriate fixings at an angle between 0 to 15 4 Supply Cable The STR1 range of roadway lanterns is suitable for use with cable with ...

Страница 3: ...ck for any signs of water ingress and remedy as necessary Check condition of all wiring and electrical components for signs of arcing or overheating Refer to Abtech technical department for advice if any components are in doubt Refit glass cover and tighten screws 3 Fault Finding Any fault finding must be carried out with the luminaire de energised and without a flammable atmosphere present Genera...

Страница 4: ...IOM STR1 Abtech Ltd Newhall Road Sheffield S9 2QJ United Kingdom IOM STR1 ABTQ210 docx Page 4 of 6 t 44 0 114 244 2424 f 44 0 114 243 4312 e sales abtech eu 2 Mounting options 3 Installation ...

Страница 5: ...IOM STR1 Abtech Ltd Newhall Road Sheffield S9 2QJ United Kingdom IOM STR1 ABTQ210 docx Page 5 of 6 t 44 0 114 244 2424 f 44 0 114 243 4312 e sales abtech eu ...

Страница 6: ...l components contain synthetic resins plastics and other inorganic compounds which may produce noxious fumes if incinerated Within the EC disposal of components must comply with WEEE directive 2002 96 EC Any local or national regulations with regard to waste disposal must also be complied with Lamps must not be incinerated Lamps should be disposed of in accordance with local or national ...

Отзывы: