![Abstrakt Instruments Avalon Скачать руководство пользователя страница 35](http://html.mh-extra.com/html/abstrakt-instruments/avalon/avalon_reference-manual_453570035.webp)
35
AVALON - Reference Manual
13 TB-303 SETTINGS
13.1 ANALOG VOICE
The analog voice is backwards compatible with the TB-303. The
additional features can be viewed as a
layer on top
of the original TB-
303 subset of controls. To limit the Avalon sound capabilities to that
of the TB-303 use the settings as shown above and described below:
13.1.1 OSCILLATORS
The sub oscillator should not be used. Set the
SUB/INPUT
control to
the minimum setting.
13
13.1.2 FILTER
If the exact
CUTOFF
range of the TB-303 is desired see Appendix A for
adjustment options. The Avalon ships with default settings that give
an extended range.
TRACKING
should be set the minimum (off) setting as it is not found
on the TB-303.
IA
13.1.3 FILTER ENVELOPE
If the exact range of
ENV MOD
(filter envelope modulation) is desired
see Appendix A for adjustment options. The Avalon ships with default
settings that allow envelope modulation to be turned off completely
when the control is a the minimum setting.
Set the
ACC DECAY
control to minimum as this corresponds to the
fixed setting of the TB-303.
13.1.4 VCA ENVELOPE
The TB-303 has a fixed VCA Decay time of 3s. This is equivalent to the
3 o'clock position of the
VCA DECAY
control.
13.1.5 MODULATION ENVELOPE
The modulation envelope should not be used. Set the
VCF DEPTH
and
VCA DEPTH
controls to the center-off position.
13.2 SEQUENCER
To limit the sequencer to TB-303 behavior you'll have to ignore
several pattern write modes and the additional pattern step
attributes.
13.2.1 PATTERN WRITE MODES
To program the sequencer like the TB -303 use PITCH & TIME STEP
ENTRY MODES as described in section 5.3. You will still need to set
the pattern length as described in section 5.2.3.1.
The TB-303 does not include the following pattern write modes:
Normal Mode
Realtime Mode
Record Mode
13.2.2 PATTERN MODIFIERS
Do not use the following pattern modifiers
(the default settings
correspond to the TB-303):
Pattern Length (use 16 steps max)
Pattern Direction
Shuffle
Pattern Rotate
Pattern Randomize
Filter B Mode
13.2.3 PATTERN STEP ATTRIBUTES
Do not use the following step attributes
(the default settings
correspond to the TB-303):
Modulation Envelope Triggers
Slide Time
Filter CV Offset
Gate Length
Active Steps
14 BLOCK DIAGRAM