Precautions

WARNING! All wiring must be performed by a qualified electri-
cian or instrumentation engineer. See diagram for terminal des-
ignations and wiring examples. Consult factory for assistance. 
WARNING! Avoid shock hazards! Turn signal input, output, and 
power off before connecting or disconnecting wiring, or remov-
ing or installing module.

Précautions

ATTENTION! Tout le câblage doit être effectué par un élec-
tricien ou ingénieur en instrumentation qualifié. Voir le dia-
gramme pour désignations des bornes et des exemples de 
câblage. Consulter l'usine pour assistance.
ATTENTION! Éviter les risques de choc! Fermez le signal 
d'entrée, le signal de sortie et l'alimentation électrique avant 
de connecter ou de déconnecter le câblage, ou de retirer ou 
d'installer le module. 

Range Selection

See model/serial number label for any applicable options or 
custom ranges. Select ranges before installation.
See table below for module output range settings. From the 
table, find the switch setting that matches your output range. 
Make sure to set the V—I switch for voltage or current output 
respectively.

Socket and Mounting

The module installation requires a protective panel or enclosure. 
Use API 008 or finger-safe API 008 FS socket.
The socket clips to a standard 35 mm DIN rail or can be 
attached to a flat surface using the two mounting holes.

Electrical Connections

See model/serial number label for module power requirements, 
and any applicable options or custom ranges. 
Polarity must be observed for input and out output wiring con-
nections. If the output does not function, check switch settings 
and wiring polarity.

Signal Input Terminals

The potentiometer must be connected to all three signal input 
terminals as shown. 0-100% of the potentiometer range must 
be used. The API 4008 G utilizes a stable 1 VDC source to 
excite the potentiometer. 

Installation and Setup 

API 4008 G

Signal Output Terminals

Polarity must be observed when connecting the signal output to 

the load. The positive connection (+) is connected to terminal 7 

and the negative (–) is connected to terminal 8. 
Note that with a mA current output the module provides power 

to the output loop.
For ranges that fall between the listed ranges use the next 

highest setting and trim the output signal with the zero and 

span potentiometers. 

Module Power

Check model/serial number label for module operating voltage 

to make sure it matches available power.
AC power is connected to terminals 1 and 3. 
For DC powered modules, polarity MUST be observed. 

Positive (+) is wired to terminal 1 

Negative (–) is wired to terminal 3 

Calibration

After the API 4008 G range switches are set, and the module is 

installed and powered, top-mounted Zero and Span potentiom-

eters are available to fine-tune the module output.
Note: Perform the following calibration procedure any time 

switch settings are changed.
1.  Apply power to the module and allow a minimum 20 minute 

warm up time.

2.  Set the input potentiometer to its minimum value to provide 

a minimum input to the module.

3. Connect an accurate measurement device to the module

output. Adjust the module’s Zero potentiometer for the

exact minimum output desired. The Zero control should

only be adjusted when the input signal is at its minimum
to produce the corresponding minimum output signal. For 
example: 4 mA for a 4-20 mA output or –10 V for a ±10V
output.

4. Set the input potentiometer at its maximum, and then

adjust the module’s Span pot for the exact maximum output 

desired. The Span control should only be adjusted when the 

input signal is at its maximum. This will produce the cor-

responding maximum output signal. Example: for 4-20 mA

output signal, the Span control will provide adjustment for

the 20 mA or high end of the signal.

5.  Repeat adjustments for maximum accuracy.

Output Test Function

The Test button may be pushed to provide a fixed output when 

depressed. This will drive the device on the output side of the 

loop (a panel meter, chart recorder, etc.) with a known good 

signal that can be used as a system diagnostic aid during initial 

start-up or during troubleshooting.
It can be adjusted to vary the output signal from 0 to 100% 

of the calibrated output range. When released, the output will 

return to normal.
Turn the multi-turn Test Range potentiometer while holding 

the Test Switch depressed until the desired output test level 

is reached. 

Operation

The API 4008 G utilizes a stable 1 VDC source to excite the 

potentiometer. This voltage is stabilized against the potentiom-

eter resistance value variations over the entire operating range. 
The resulting potentiometer wiper voltage is amplified and 

passed through an optical coupler to the output stage where it 

is scaled to the desired output range.
The green LoopTracker

®

 input LED provides a visual indication 

that a signal is being sensed by the input circuitry of the mod-

ule. It also indicates the input signal strength by changing in 

intensity as the process changes from minimum to maximum.
If the LED fails to illuminate, or fails to change in intensity as 

the process changes, check the module power or signal input 

wiring. Note that it may be difficult to see the LEDs under bright 

lighting conditions.
The red LoopTracker output LED provides a visual indication 

that the output signal is functioning. It becomes brighter as 

the input and the corresponding output change from minimum 

to maximum. 
For current outputs, the red LED will only light if the output loop 

current path is complete. For either current or voltage outputs, 

failure to illuminate or a failure to change in intensity as the 

process changes may indicate a problem with the module 

power or signal output wiring. 

8

7

(–)

(+)

PLC, Display, 

Recorder w. 

Voltage Input

Voltage output

AC or DC (–) 

Module power 

AC or DC 

(+)

Socket top 

view

2

1

8

7

3

4

5

6

(–)

(+)

Sourcing mA 

output  

20 V loop power

PLC, Display, 

Recorder w. 

mA Input

R

i

Key down 

when 

panel 

mounting

Full Scale

 

Wiper Arm

 

Minimum

Potentiometer Input

Potentiometer Full Scale 

and Minimum may be 

switched for reverse 

output

Voltage Output

A B

Current Output

A B

0-1 VDC

V 0

0-2 mA

I 0

0-2 VDC

V 8

0-4 mA

I 8

0-4 VDC

V 1

0-8 mA

I 1

0-5 VDC

V 9

0-10 mA

I 9

0-8 VDC

V 2

0-16 mA

I 2

0-10 VDC

V 3

0-20 mA

I 3

1-5 VDC

V 6

2-10 mA

I 6

2-10 VDC

V 7

4-20 mA

I 7

±5 VDC

V 4

±10 VDC

V 5

API 008 FS

 

8-Pin Finger Safe Socket

1.063 

[27.00]

2.559 

[65.00]

0.126 

[3.20] 

Dia.

1.181 [30.00]

0.220 [5.60]

8

7

6

5

4

1

2

3

1.496 [38.00]

Contacts: Nickel plated 

brass, 10 Amps max.
Screws: M3, zinc 

plated steel
Wiring: #14 AWG solid 

or stranded

Top View

Terminal Location

8

7

6

5

4

1

2

3

API 008

 

8-Pin Socket

0.165 

[4.19] 

Dia.

1.06 

[26.9]

2

1

3

4

5

6

7

8

0.312 [7.92]

0.98 

[24.9]

1.295 

[32.89]

1.61 [40.9]

Contacts: Nickel plated 

brass, 10 Amps max.

Screws: 6-32 x 1/4", zinc 

plated steel

Wiring: #12 to #22 AWG 

solid or stranded, or 1/4" 

or 5/16" spade lug

2.11 

[53.6]

Terminal Location

Top View

8

7

6

5

4

1

2

3

0

5

1

6

4

2

9

7

3

8

A

4008 G 

B

Output

Select

I     V

Output

Range

Potentiometer Input

 Terminal

Zero or low end of potentiometer

 4 

Potentiometer wiper arm

 5

Full scale or high side of potentiometer

 6 

(

+1 VDC)

API maintains a constant effort to upgrade and improve its products. 

Specifications are subject to change without notice. See api-usa.com for 

latest product information. Consult factory for your specific requirements.

WARNING:

 This product can expose you to chemicals includ-

ing lead and nickel, which are known to the State of California 

to cause cancer or birth defects or other reproductive harm. 

For more information go to www.P65Warnings.ca.gov