![Absolute Ozone NANO 15 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/absolute-ozone/nano-15/nano-15_operators-manual_3558172018.webp)
18
SECTION 4 MAINTENANCE AND SERVICE
4A Preventative Maintenance
Generally, Absolute Ozone
®
is maintenance-free although it is
useful to check the Ozone Generator for proper operation:
1. Make sure there are no warnings on the LCD screen.
2. Inspect visually all gas, power and signal cables, and con-
nectors
3. Make sure that all air vents are not obstructed.
4B. Troubleshooting
Knowledge of electrical applications is required for trouble-
shooting. Contact a certified electrician if you are unsure of
your ability to service the equipment. If any problem persists,
please call (+1)780-486-3761. We will have one of our system
engineers discuss your situation with you over the phone.
Monthly:
1. Make sure that all system equipment (oxygen concentra-
tor, air compressor, etc.) is maintained according to the
manufacturer
2. Remove and replace or clean filter cartridges and other
devices if installed and required.
3. Perform general cleaning of cabinet exterior after dis-
connecting the equipment from the electrical source.
4. Using clean/dry compressed air, or a vacuum cleaner
blow out the interior or vacuum the cabinet, taking spe-