5. Connecting the Cables 

5.1. Power cables 

AC power input is via a standard IEC inlet socket. Operating voltage must only be 
changed by an authorized service agent. 

There are four DC power cables connecting the Power Supply and the Signal Stage. 
Each DC connection has a different number of pins. The 2-pin cable connects to the 
2-pin sockets, the 3-pin cable connects to the 3-pin socket etc. The DC connectors 
lock into the corresponding socket with a twisting ring. Connect and lock all four DC 
power cables before powering-up the system. Never connect or disconnect any 
power cable while the unit is operating. Some of the pins carry high voltages, so it is 
important to never touch any Power Supply DC Output sockets while the unit is 
operating. Also wait at least 30 seconds before disconnecting any cables after 
powering down the unit.  

5.2. Signal Cables 

You can connect two separate arms/cartridges to the Signal Stage at the same time. 
The selector switch between the inputs selects the active input channel. Ground 
point is common for both input channels.  

6. Operating the Unit 

6.1. General Operation 

Absolare Phono Stage will be ready to operate 40 seconds after turning on the 
power but attain full performance after 15 to 30 minutes.  

Signal ground and chassis/power ground is separate inside the Signal Stage and 
they are connected by a high pass filter to reduce hum and noise. The ground point 
near the inputs is connected to the chassis ground. The outside parts of the RCA 
output connectors are connected to signal ground.  

There are no adjustments required other than cartridge loading. As you can connect 
two separate arms/cartridges to the Signal Stage at the same time, there are 
separate loading options for each input. To provide more levels in total and a better 
match for each cartridge, load values are not the same between channels. If the 
preset levels do not match the desired value exactly, you can install your own load 
resistors for each input channel (

see section 6.2. for installing custom resistors

). 

There are five factory-fixed plus one custom load level for each input.  

Custom resistors can be accessed via the input tube cover on the back of the unit.  

Содержание Phono Stage

Страница 1: ...ABSOLARE Phono Stage User Manual ...

Страница 2: ...2 ABSOLARE Phono Stage User Manual 1 2 ...

Страница 3: ...d Warnings 4 3 Unpacking and Placement 5 4 Installing the Tubes 6 5 Connecting the Cables 8 5 1 Power cables 8 5 2 Signal Cables 8 6 Operating the Unit 8 6 1 General Operation 8 6 2 Installing Changing Custom Load Resistors 9 7 Troubleshooting and Maintenance 10 8 Technical Specifications 11 ...

Страница 4: ...ransformers and also separate DC regulators for input and output sections of the Signal Stage Two input channels with adjustable loading resistance are directly coupled to the input tubes 2 Safety Issues and Warnings Be sure the voltage setting of the unit matches the applied voltage to power input Operating voltage is fixed and must only be changed by an authorized service agent Do not touch tube...

Страница 5: ... be supported by separate support feet They do not have support feet fixed in place Feet can affect the sound quality significantly Feet must be positioned underneath each unit in direct contact with the aluminum base plate not the leather clad MDF covers There are three areas where the aluminum base plate is exposed through openings in the leather clad MDF bottom plate You can use either three or...

Страница 6: ...ur tubes are located inside the unit accessible only by removing the small cover on the rear panel Placement of the upper tubes is shown below You may receive the unit with the internal tubes already pre installed If this is not the case or you wish to replace them yourself you should remove the four small hex screws on the corners of the small cover on the rear panel as indicated below ...

Страница 7: ...ns before installing the tubes into the sockets PLEASE NOTE WE417 tubes have different pin configuration to 6C45PI tubes You must either have the WE417 version of the phono stage or use a conversion adapter Otherwise the unit will not work and permanent damage may occur 12AX7 12AU7 6C45PI tubes have one missing pin acting as a correct positioning key Align the missing pin with the missing hole in ...

Страница 8: ... the inputs selects the active input channel Ground point is common for both input channels 6 Operating the Unit 6 1 General Operation Absolare Phono Stage will be ready to operate 40 seconds after turning on the power but attain full performance after 15 to 30 minutes Signal ground and chassis power ground is separate inside the Signal Stage and they are connected by a high pass filter to reduce ...

Страница 9: ...value Input capacitance is fixed at 100pF You can use the 47K setting for MM cartridges 6 2 Installing Changing Custom Load Resistors Custom load resistors are accessible from behind the small back cover First you should remove the four hex screws on the corners of the small cover on the rear panel Then you can change the resistors to any desired value There are straight wires in place of the resi...

Страница 10: ...Both indicator lights are on but tube heaters are not glowing Check all DC power cords Both indicator lights are on tube heaters are glowing but no sound Check all DC power cords Check the input selector Check resistor loading custom level is short circuited as factory default Check output cables Noise hum in the sound Check grounding of input cables Check resistor loading 47K setting may increase...

Страница 11: ...independent inputs A B with input selector switch 5 factory fixed 1 custom cartridge loading level for each input Custom resistors can be accessed via input tube cover on the back of the unit Input A loading 68 Ω 150 Ω 330 Ω 680 Ω 47 kΩ custom value Input B loading 47 Ω 100 Ω 220 Ω 470 Ω 1 kΩ custom value Input capacitance 100 pF Direct coupling to input no step up transformer Gain 61 dB fixed Out...

Страница 12: ...USA LLC 40 Pemberton Road Nashua New Hampshire 03063 Phone 212 229 1842 E mail info absolare com ABSOLARE SERVICE EUROPE Mozartstraat 157 1962AL Heemskerk Netherlands Phone 31 61 399 3049 E mail info absolare nl ...

Страница 13: ...13 ABSOLARE Phono Stage User Manual 1 2 2020 ABSOLARE ...

Отзывы: