KL II
Series User Manual 32
6
No control system
detected
1. Check the USB cable;
2. Check whether the computer USB port is malfunctioning;
3. Update the USB driver;
4. Replace the USB cable;
5. Replace the sending card;
7
No multi-function card
detected
1. Check whether the distribution box is in the automatic
state;
2. Check whether the multi-function card is powered;
3. Replace the power supply of the multi-function card;
4. Check whether the main data cable is inserted into the
wrong data port;
5. Check whether the sending card data port is
malfunctioning;
6. Re-add the multi-function card;
7. Replace the multi-function card;
8. Replace the sending card;
8
No full screen display
1. Check whether the setting of the playback window is
normal;
2. Check the output resolution of the video processor;
3. Check the output window of the video processor;
©2022
Shenzhen Absen Optoelectronics Co., Ltd. All rights reserved.
Without the written permission of the company, any unit or individual shall not extract or copy
part or all of the content of this document without authorization, and shall not disseminate it