background image

Product Introduction 

 

1.

 

Product Introduction 

The iCon series products is Absen's conference screen products for high-end 

conferencing solutions. Products are mainly used in conference rooms, education and 

other applications. 

iCon's high-end conference screen solution will create a bright, open and efficient 

meeting environment to enhance the audience's attention and enhance the impact of the 

speech, and promote the efficiency of the meeting. 

The iCon series has the following products: iCon C110, iCon C138, iCon C165 and iCon 

C220. In the future, according to market demand, other specifications will be 

introduced: iCon E110, iCon E138, iCon E165, iCon E192. The iCon C110, iCon E110, iCon 

C138, and iCon E138 products are mainly used in the use of 30-person conference rooms. 

The iCon C165 and iCon E165 products are mainly used in the 60-person conference room. 

The iCon C220 and iCon E192 products are mainly used in 100-person. The use scene of 

the conference room.                              

 

 

Содержание iCon C110

Страница 1: ...iCon series User Manual Shenzhen Absen Optoelectronic Co Ltd ...

Страница 2: ...Table of content Safety Information 03 Product Introduction 06 About iCon series 06 Product Specifications 07 Product Installation 16 Service and Maintenance 29 ...

Страница 3: ...this manual carefully before installing powering up operating and maintenance of this product Follow safety instructions in this manual and on the product If you have any questions please seek help from Absen WARNING Please read the Safety Measures listed in this section carefully before installing switching on operating and maintenance of this product WARNING Safety Risk Might cause equipment dam...

Страница 4: ...t a location near the product and should be clearly visible and easily reached This way in case of any failure the power can be promptly disconnected Before using this product check all electrical distribution equipment cables and all connected devices and make sure all meet current requirements Use appropriate power cords Please select the appropriate power cord according to the required power an...

Страница 5: ...reen from within a 1 meter distance Do not use any optical devices that have converging functions to look at the screen to avoid burning the eyes Product Disposal Any component that has a recycling bin label can be recycled For more information on collecting reusing and recycling please contact the local or regional waste management unit Please contact us directly for detailed environmental perfor...

Страница 6: ...e impact of the speech and promote the efficiency of the meeting The iCon series has the following products iCon C110 iCon C138 iCon C165 and iCon C220 In the future according to market demand other specifications will be introduced iCon E110 iCon E138 iCon E165 iCon E192 The iCon C110 iCon E110 iCon C138 and iCon E138 products are mainly used in the use of 30 person conference rooms The iCon C165...

Страница 7: ......

Страница 8: ......

Страница 9: ...rame Frequency Hz 50 60 Signal Transmission Distance m UTP cable 100 m Single mode fiber 10 km Optical Parameters Brightness nit 350 Horizontal Viewing Angle 140 Vertical Viewing Angle 140 Electrical Parameters AC Input Voltage V 200 240 AC Input Frequency Hz 50 60 Maximum AC Input Power W m2 360 Average AC Input Power W m2 120 Environmental Parameters Storage Temperature C 40 60 Working Temperatu...

Страница 10: ...e Frequency Hz 50 60 Signal Transmission Distance m UTP cable 100 m Single mode fiber 10 km Optical Parameters Brightness nit 350 Horizontal Viewing Angle 140 Vertical Viewing Angle 140 Electrical Parameters AC Input Voltage V 200 240 100 240 AC Input Frequency Hz 50 60 Maximum AC Input Power W m2 360 Average AC Input Power W m2 120 Environmental Parameters Storage Temperature C 40 60 Working Temp...

Страница 11: ...Picture Frame Frequency Hz 50 60 Signal Transmission Distance m UTP cable 100 m Single mode fiber 10 km Optical Parameters Brightness nit 350 Horizontal Viewing Angle 140 Vertical Viewing Angle 140 Electrical Parameters AC Input Voltage V 100 240 AC Input Frequency Hz 50 60 Maximum AC Input Power W m2 360 Average AC Input Power W m2 120 Environmental Parameters Storage Temperature C 40 60 Working ...

Страница 12: ...e Frame Frequency Hz 50 60 Signal Transmission Distance m UTP cable 100 m Single mode fiber 10 km Optical Parameters Brightness nit 350 Horizontal Viewing Angle 140 Vertical Viewing Angle 140 Electrical Parameters AC Input Voltage V 100 240 AC Input Frequency Hz 50 60 Maximum AC Input Power W m2 360 Average AC Input Power W m2 120 Environmental Parameters Storage Temperature C 40 60 Working Temper...

Страница 13: ...2 Cabinet dimension figure 3 Module dimension figure ...

Страница 14: ...Product Components 2 1 Cabinet Introduction 2 2 HDMI cable for vertical connections in between the cabinets 0 5m ...

Страница 15: ...n the cabinets 0 95m 2 4 Power Cable 1 for vertical connections in between the cabinets 0 26 m long Power Cable 2 for vertical connections in between the cabinets 0 5 m long 2 5 Main Power Cable 10 m long 2 5mm 2 6 Main HDMI cable 5m long ...

Страница 16: ...e position is the distance from the end face of the beam is 100mm the distance between the upper and lower wall joints is 900mm The distance between the lower frame and the wall joint is 305mm as shown in the figure below Step2 According to the position of the wall joint the hole is φ12mm deep and 55mm the expansion bolt M8x80 is used the wall joint piece is fixed and the flange nut M8 is fixed No...

Страница 17: ... a total of 3 use the 3mm hex wrench to screw in the front side does not install the slot connector because the front may need to put the T nut to fix the hanging plate Note There is a tapping on one end of the beam and the tapping end cannot be placed in the middle Placement in the middle will result in the vertical beam not being fixed Cylindrical head hexagon bolts M8x30 fixed T bolt M6x16 and ...

Страница 18: ...the hanging plate as shown below Note First screw all T nuts and screws into the middle and side hanging plate waist holes Step 6 Fix the first side hanging plate to the beam and align the side of the hanging plate with the cross section of the beam Note Side hang board alignment T nut Large flat head screw M6x10 Article 1 hanging board ...

Страница 19: ...Step 7 Install the side hanging plate and the middle hanging plate from left to right Step 8 Put in the box and lock it ...

Страница 20: ...ll the border and corner Install from the bottom up pay attention to the large frame screw M6x10 fixed frame to the box Step 10 Fixed distribution box ship type switch etc The position is the bottom of the cabinet ...

Страница 21: ... iCon C165 E165 installation iCon E192 installation ...

Страница 22: ... iCon C220 installation ...

Страница 23: ...bumpers to the truss or the steel structure Connect the bumpers together using the metal connectors and make sure they are level Cabinet installation Assemble the cabinets from top down layer by layer align the coffin locks with the corresponding holes on the bumpers ...

Страница 24: ......

Страница 25: ...During installation make sure all the coffin locks are tightened in the direction of arrow as shown in the illustration ...

Страница 26: ... source to the screen please check power and data cables connections carefully and make sure they are wired correctly Use a multimeter to test the L N and PE lines in AC power input port and make sure the tree lines are not short circuited Power cable connection description RJ45 USB HDMI IN HDMI OUT ...

Страница 27: ...creen power cable can carry up to 32 cabinets ie iCon C110 iCon E110 iCon C138 iCon E138 screen comes standard with 1 3 2 5mm screen power cord iCon C165 iCon E165 iCon E192 iCon C220 screen comes standard with 2 3 2 5mm joint power cables ...

Страница 28: ...DMI Cabling Notes The signal line adopts HDMI cable and the S type is connected up and down Please calculate the resolution according to each box pixel Each HDMI cable can control up to 1920 1080 pixels ...

Страница 29: ...service tool clockwise all the way Step 2 Place the front service tool onto the module tightly and rotate the two rotation handles counterclockwise all the way Step 3 Hold the two handles on the tool and firmly pull the module out of its frame Step 4 Take modules off and place them in a safe area and then turn the two rotation handles clockwise all the way ...

Страница 30: ... a multi meter to test the AC input L N PE and DC output VCC GND to determine whether there is a short circuit If a short circuit has been found please examine the circuit carefully Power up the cabinets only after making sure all the circuits are working properly ...

Страница 31: ...en Absen Optoelectronic Co Ltd reserves the rights to modify contents without any further notice Shenzhen Absen Optoelectronic Co Ltd 18 20F Building 3A Cloud Park Bantian Longgang District Shenzhen 518129 P R China T 86 755 89747399 E absen absen com W www absen com ...

Отзывы: