Installation procedure
Installation Notes:
The panel is waterproof front and rear, and can be directly installed naked. It can be installed
from front and rear. It cannot be installed directly against the wall.
When the panel is installed naked, there is no need for any covering on the edges or any other
decorations. The back of the panel is directly exposed outside, which relies on the external
environment for natural heat dissipation without other heat dissipation equipment.
When the back space of the panel is fully closed, heat dissipation equipment need to be installed
inside the closed space, such as air conditioner and exhaust fan, etc. About 1 air conditioner for
every 15 square meters screen.
The steel support structure of the panel must be designed and constructed in strict accordance
with our company's panel drawings. At least 60cm-80cm maintenance space should be reserved
for rear installation and 30-40cm for front installation.
During installation, the panel should be installed from the middle position at the bottom row of
the steel structure and installed from bottom to top. Fix the panel on the structure in turn with
connecting plates and M10x60mm bolts.
In order to facilitate the front maintenance of the power supply box, when the screen body is
used for front installation against the wall, a rear maintenance space of at least 25 cm must be
reserved in the sealed space on the back of the box.
Front-installation:
When front-installing the cabinet, it should be reserved at least 20cm on the back of the
cabinet. For facilitate subsequent after-sales service, please ensure that the rear-maintenance
space is not obscured.
1.Remove the module first
;
Use the front maintenance tool to insert into the front maintenance
hole of the module, rotate it counterclockwise then remove the module.
2.
Place the panel on the horizontal frame of the steel structure, use 40*40 square tubes between
panels;
3.Pass the screws and connecting pieces through the space of the cabinet, and then tighten the
screws;
4
.
The box body and the square pass are fixed with connecting pieces;