Absco Large Gable Roof Shed Notes
• 1.S All structural steelwork shall have a corrosion protection system applied consistent with AS/NZS 2312-
2002.
• 2.S All structural steelwork detailed within this installation manual shall be minimum Grade 550 for roll formed
sections (including roof and wall sheeting and portal frame members) and Grade 250 for angle sections.
• 3.S All multi purpose and anchor brackets for connection onto the supporting reinforced concrete slab
(includes 45x45x3EA x 34mm long and 47x47x1.9EA x 80 long) shall be minimum Grade 450.
• 4.S All portal frame knee and apex plates shall be minimum Grade 450
• 5.S All roof, and wall sheeting shall be minimum base metal thickness of 0.3mm
• 6.S All portal frame members shall be minimum base metal thickness of 0.75mm.
• 7.S All snaptite channels and jambs shall be minimum base metal thickness of 0.42mm
• 8.S All top hats shall be minimum base metal thickness of 1.0mm
• 9.S All portal frame knee and apex plates shall be minimum base metal thickness 1.0mm
• 10.S All screw fasteners shall be Phil Pan Head Zinc Plated #8 x 3/4” (STP0820)
• 11.S All bolt fasteners for anchoring shall be M10 minimum grade 4.6/S
• 12.S Installation of screw fasteners shall generally be undertaken in accordance with the relevant provisions
of AS1562.
Steelwork