20
ENG
Charge maintainer/maintenance charge: This is used to safely charge the battery over a
long period of time. During this phase, the battery icon is displayed continuously and
the battery can be charged to 100%. This also prevents the battery from automatically
discharging. A long charging period with a low current can prevent vulcanisation.
Graph of the charging information:
Charging mode:
Automatic identification of the battery voltage: 6 or 12 V. For 6 V batteries, the only
option available is a 6 V/1 A (slow) charging mode and for 12 V batteries, there are 3
recharging modes available, as follows:
•
6 V/1 Amp
Slow charging mode (default)
•
12 V/1 Amp
Slow charging mode
•
12 V/4 Amp
Quick charging mode
•
12 V/4 Amp LOW TEMP Low-temperature charging mode (Ambient temp.
<
10°C)
The minimum voltages for the automatic identification of 6 V and 12 V batteries are 3
and 7.4 V respectively.
Voltage
Volts
Current
Amperes
Pre-
charge
Constant
current
charging
Constant
voltage
charging
Charge
maintainer