![ABS RFC-16A Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/abs/rfc-16a/rfc-16a_owners-manual_3539917005.webp)
5
starting this new appliance, allow the cabinet to operate a minimum of eight hours or until
it has started cycling normally before placing product in the cabinet. The motor compressor
may start and stop several times when the unit is first started or after defrosting, especially
if the weather is very hot. This is only normal functioning of the motor overload protector.
The motor compressor will cycle normally as soon as the excess heat has been removed.
Temperature control
NOTE: The controls are preset at the factory to provide the desired air and product
temperatures inside of the unit and require no further adjustment. Please contact the
manufacturer’s Technical Support Department before making any adjustment to make sure
the adjustment is necessary and, if so, to ensure it is performed properly.
Set-current time and day. When the unit is switched on, it is often necessary to set the time and day
(depending on how long it has been disconnected from power)
Press SET and V simultaniously and hold for 3 seconds.
The rtc symbol will appear. Release.
Push the SET key to scroll to the first setting, which is Hur (hour). Push SET again and set the hour by
using the up and down arrows. Push SET again to lock in the hour.
Repeat the same sequence for the MIN and dAy settings.
When you have finished, exit by pushing SET and Up simultaniously and holding for 15 seconds
Control operation.
The Factory set Freezer-Fridge setting will be sufficient while your unit cools. Meanwhile, you can
familiarize yourself with important functions:
How to see the set point. Push and release the SET tosee the set point . Push again to return to probe
value(actual chamber temperature).
How to change the set point. Push the SET key for more than 3 seconds and the “°C” symbol will start
blinking. Release the set key and use the up and down arrows.