background image

Part number 20080, Rev 0 

10 

 

QUICK TROUBLESHOOTING GUIDE 

Check these items before calling for service 

PROBLEM: 

POSSIBLE CAUSE / SOULTIONS: 

Unit does not run 

 

Electrical circuit is not 110-120V 60Hz. 

 

The power cord is not plugged in. 

 

No power at electrical outlet. Check to make sure 

breaker is not tripped or fuse is not blown. Additionally, 

make sure unit is not plugged into a Ground Fault Circuit 

Interrupter (GFCI) type of outlet.  

Unit does not maintain at the 
proper temperature 

 

Check the room temperature.  We recommend the 

refrigerator or freezer should be placed in the air 

conditioned room between 65°F to 85°F.  If the room 

temp is too warm, the refrigerator or freezer may not be 

able to maintain the interior temp at proper range.   

 

Door is not closed properly. 

 

Amount of stored product is overloaded. 

 

Product replacements are pushed against rear wall or 

interrupted the proper refrigerator air circulation.  For 

the proper air circulation, place the products evenly on 

each shelf.  Do not push against the refrigerator’s rear or 

side walls. 

 

Evaporator is blocked by frost or ice.  Remove the 

products, unplug the refrigerator or freezer power, and 

allow the unit to defrost.  If the problem still exists, call 

for service.  

 

3

rd

 party thermometer is placed incorrectly. For proper 

temperature monitoring, the thermometer should be 

place in the middle of refrigerator. 

 

PLEASE NOTE

!  Prior to shipment, each refrigerator and freezer 

has been calibrated and tested at proper temperature range. 

Appliance runs too long 

 

Prolong door openings. 

 

Control set too cold. 

 

Room temperature is high which will make the unit work 

harder to keep cool.  

Temperature of external wall 
surface is warm 

 

The exterior walls can be as much as 30 degrees warmer 

than room temperature due to the embedded 

condenser coils. This is normal when the unit is 

operating.   

 

Содержание ABT-23SS-GP

Страница 1: ...delivery Make sure you get a signed copy Send a written request for an inspection to the carrier B Concealed Damage This type of damage may not be discovered until the unit is being unpacked When con...

Страница 2: ...ARTMENT please have the unit s model and serial number ready as well as the problem description The model and serial number is located on the serial tag which can be found on the interior left upper w...

Страница 3: ...y receipt acknowledging the damage This has to happen at the time of delivery or it won t happen at all Keep a copy for your records and send another to the carrier s damage claims department along wi...

Страница 4: ...o this cabinet must conform to all National and Local Electrical Codes Consult the cabinet Serial Data plate for voltage cycle phase and amp requirements before making connection VOLTAGE SHOULD NOT VA...

Страница 5: ...INSTALLATION Hook shelf clips onto pilaster strips see Illustration Position all four shelf clips equal in distance from the floor for flat shelves Wire shelves are oriented so that cross support bar...

Страница 6: ...n cooling of the product When loading the top shelf avoid blocking the evaporator fan s There should be at least 4 inches of clearance below the fan s to allow proper air flow Do not overload the unit...

Страница 7: ...of an alarm condition Beeper for audible indication of an alarm condition A preprogrammed 5 minute delay from the time a setpoint is attained until an alarm condition is declared This prevents spurio...

Страница 8: ...wn arrow The display will show Pon The control keys are now unlocked and you can perform the programming functions below Adjusting the temperature control setpoints NOTE The temperature control setpoi...

Страница 9: ...to display the current setting either C for Celsius or F for Fahrenheit Use the UP or DOWN key to choose the desired setting Press SET again to lock it in Press SET and UP to return to Operating Mode...

Страница 10: ...placements are pushed against rear wall or interrupted the proper refrigerator air circulation For the proper air circulation place the products evenly on each shelf Do not push against the refrigerat...

Страница 11: ...prevent leakage Door will not close The unit is not level Refer to the Leveling section at the beginning of this manual Check for dirt and debris or items passing through the door seal MOISTURE DURIN...

Страница 12: ...ill not harm the steel s passive layer Stainless steel pads can also be used but the scrubbing motion must be in the directing of the polishing lines Clean with the polish lines Some stainless steels...

Страница 13: ...ywhere We recognize it quickly on iron and steel as unsightly yellow orange rust Such metals are called active because they actively corrode in the natural environment Contrary to popular belief Stain...

Страница 14: ...Y In addition to the two 2 year warranty stated above Horizon Scientific Inc warrants its hermetically and semi hermetically sealed compressors to be free from defects in both material and workmanship...

Страница 15: ...od or other external causes It does not apply to defects resulting from failure to properly install operate or maintain the product in accordance with the printed instructions provided or damage cause...

Отзывы: