OPERATION
4
Control Panel
1. Timers
On top of the operation panel, there are three timers: Timer , is for slow
speed; Timer
Ⅲ
is for fast speed. Each Timer has three digits.
The unit of A and B is minute while C is 10 seconds, for example: 0.1 is 10
seconds, 1.2 is 1 minute and 20 seconds.
The timers are set by and buttons. Press button to
increase time, the maximum set time is 20 minutes. After 20 minutes is
reached, the timer returns to 0 minute again. Press button to lessen
the time on the timer.
When the spiral mixer is switched ON, timers will show the set time. The
timer will only be operative when mixer is in AUTO mode. The timer will
start automatically when the ON button is pressed. The slow speed timer I
will run first and then the slow speed timer , the fast speed timer begin to
run when the timer ,runs to zero. When all timers reach zero, the
machine will stop mixing.
When the spiral mixer safety guard is lifted, the timer will stop with the mixer
and resume when the guard is moved down and the ON button is pressed.
When the OFF button is pressed, the timers will reset to the original set
time.