30
7 Communication interfaces
7.1
7.1
7.1
7.1
Standard communication interfaces
7.1.1
7.1.1
7.1.1
7.1.1
RS-232 interface definition
The RS-232 interface must be configured as follows:
Baud Rate
9600 bps
Data Length
8 bits
Stop Bit
1
Parity
None
RS-232 Pin assignments are as follows (The connector is male.)
7.1.2
7.1.2
7.1.2
7.1.2
RS-485 interface definition
The RS-485 interface must be configured as follows:
Baud Rate
9600 bps
Data Length
8 bits
Stop Bit
1
Parity
None
Pin 2: RS-232 Rx
Pin 3: RS-232 Tx
Pin 5: Ground
1
2
3
4
5
6
7
8
9
31
RS-485 pin assignments are as follows:
PIN 3 = 485 GND
PIN 4 = EPO GND
PIN 5 = EPO
PIN 7 = 485
A/Data+
PIN 8 = 485
B/Data-
7.1.3
7.1.3
7.1.3
7.1.3
EPO (Emergency Power Off) RJ45 connector
To activate EPO pin 4 and pin 5 must be shorted.
Make sure the RJ45 plug is properly
attached to the wire.
Ensure that the EPO function operates
properly with your application by testing the
inverter while it is injecting current. Check
that the inverter stops injecting current.