Fig. 4

Part descriptions & dimensions (mm)

Water supplies

 

The Nova-Flo

®

 valves are not hot or cold specific, so hot or cold water 

can be run through either side.

1. Bath and Wall Mounted taps: (See Fig. 3)

 

The water supplies for the hot and cold feeds must pass up through  

each side valve (Fig. 1, E) of the Nova-Flo

®

 unit respectively with the  

upper ¾" BSP connectors (Fig. 1, B) leading to the tap controls or mixer.

2. Bath Filler and Waste Combinations: (See Fig. 4)

 

The mixed water supply fed from the tap controls is to be split and  

directed equally to both side valves. The upper connections are then  

to be reconnected and a branch led to the filler and waste head. 

Use of a Thermostatic Mixing Valve (TMV)

 

It is recommended that a TMV be installed prior to the Nova-Flo

®

 unit. 

e.g. Thermally mixed water should be directed through one side valve 

of the Nova-Flo

®

 unit. Nova-Flo

®

 is rated at a maximum hot water 

temperature of 60 degrees Centigrade.

Purging of system

 

Once fitted, the system will need to be purged to clear any air trapped  

inside. This is done by allowing the taps to run at full flow for 1 minute,  

then turning them off. Repeat this procedure three times. Should the  

valves actuate, simply turn off the taps, wait for five seconds then turn  

them on gently. Once the system is purged of air, activation of the valves 

such as this will not occur. In some installations with an exceptionally fast 

flow rate, unexpected water shut off may occur before the bath is full. In this 

occurrence simply restrict the water flow by closing the supply valves slightly.

Testing

 

Test for leaks before replacing any bath surround or cladding.
To ensure correct operation, you are advised to check its operation  

once every six months. To do this, keep the taps on and direct water  

from a shower head or pour water from a large jug into the overflow  

outlet until activation. Whilst doing this it can be quicker to cup a cloth  

with your hand below the overflow outlet to channel more water into it.
Should the overflow system ever become clogged with soap, hair etc. 

resulting in a blockage remove the lower barb connector by rotating  

it 45 degrees anti-clockwise and clear any debris with a cotton bud or 

similar, then refit the barb connector. Care should be taken not to lose  

the o-ring. Should more intensive cleaning be required you can find  

more maintenance guidance at 

www.nova-flo.com

Resetting the water upon activation of the valves

 

If water pours down the overflow outlet, the taps will be substantially shut  

off. There will remain a small trickle of water which is intentional and reminds 

the user to turn off the taps (the overflow can easily handle this trickle).
To reset the unit, ensure there is no more water going through the 

overflow then simply turn off the taps and wait for five seconds. Upon 

opening the taps full flow is resumed. Your taps and water supply will be 

unaffected in normal use.

Recommended fittings

 

To ensure compatibility we recommend installers use the Nova-Flo

®

 

push-fit or compression fixing packs. Where the fixing pack is not used 

installers must ensure compatibility of their chosen fittings with the ¾" 

BSP side valve connections, which are designed for use with hand 

tightened plastic connectors. The lower port of each side valve should be 

connected to a flexible hose to ensure that the unit is not installed under 

tension. We recommend the use of shower pump flexible hoses or similar.

WARRANTY

 Nova-Flo

®

 (the device) is warranted to be free of defective 

parts, material and construction for a period of 2 years from date of 

purchase. The device is designed for occasional use as a preventative 

device and should not be used as a means of automatically setting your 

bath water level on a regular basis.
About Time Design Ltd (the company) and our suppliers take no 

responsibility for the quality of fitment of Nova-Flo

®

 or any loss or  

damage caused by defective installation. We recommend installation by 

a qualified professional to ensure there are no leaks and that the device 

performs according to specification. The company takes no responsibility 

for consequential loss under any circumstances. In event of queries,  

in the first instance please our helpline on +44 (0)1608 811 707. 

Nova-Flo and Flowban are registered trademarks of About Time Design Ltd

Patent Protected: GB: 2428800, 2458783, 2476539, 2476351, 2476542, 2476353, 

2476707, 2476540, 2476541, 2458783; Europe: 2279367; USA: 8215335 & 8517045.

Water Regulations Advisory Scheme Limited (WRAS Ltd.) owns WRAS Approved Product 

Certification Mark and reserves all rights to it.

Manufactured by

About Time 

Design Ltd

Distributed by

Lifescience Products Ltd
Unit 19, Cheltenham Trade Park 

Gloucestershire GL51 8LZ

Contact 

W: 

www.nova-flo.com

E:  [email protected]
T: +44 (0)1608 811707

© Copyright About Time Design Ltd, 2022

Fig. 3

Part descriptions & dimensions (mm)

These parts not supplied:

Taps.

(4 of) ¾" BSP to 22mm 

hand tighten pipe 

connectors.

Overflow outlet.

22mm pipe (Length to be 

calculated according to  

bath, taps and plumbing 

connections used).

Overflow flexy-pipe 

(trim to fit).

Flexible hose with ¾" BSP 

hand tighten connector.

IMPORTANT:

Nova-Flo

®

 must not be 

installed under any tension

Bath filler and  

waste combination.
Suitable 22mm pipe 

to tap connector.
22mm pipe (shown  

with soldered fittings). The  

lengths need to be calculated 

according to configuration.
Overflow flexy-pipe  

(trim to fit) For some  

installations a replacement 

may be necessary. A washing 

machine hose is often ideal, 

secured with Jubilee clips
(4 of) ¾" BSP to 22mm  

hand tighten pipe connectors.

Channelling mixed water supply from tap controls

Trap

Trap

These parts not supplied:

Отзывы: