A Patient Guide to BiWaze

®

 Clear System   4

Dual Lumen Breathing Circuit Setup

1.  BiWaze Clear  

Main therapy  

control unit. 

2.   Coaxial Bacterial/Viral Filter  

designed to ftiler bacterial and viral 
particles from flowing in and out of 
the control unit.  

3.  Coaxial Breathing Tube  

seperates 

the inhalation (outer path) from 
the exhalation (inner path).

4.  Aerogen

®

 Power Cable  

powers 

Aerogen Solo nebulizer

5.  Aerogen

®

 Solo Nebulizer   

vibrating mesh nebulizer for 
prescribed medication 

6.  Handset  

provides a comfortable 

grip for therapy delivery and a 
spacer for the nebulizer.

7.  Patient Interface  

there are three          

patient interface options available; 
face mask, mouthpiece, and a 
flexible trach adapter.

1

3

4

2

5

6

PAT I E NT I NT E R FAC E S

Leaks in the patient interface can decrease the effectiveness of the therapy. 

Some people may need to have their head supported from behind to prevent leaks  
when using a face mask.

When using a mouthpiece, you may need to use a nose clip to prevent leaks.

Note: Always follow the prescribed therapy protocol from your physician.

7

Содержание BiWaze Clear System

Страница 1: ...a bre a t h of f re s h c a re A Patient Guide to BiWaze Clear System...

Страница 2: ...irreversible leading to chronic respiratory failure and other serious health complications Airway clearance techniques ACTs loosen thick sticky mucus so it can be cleared from your lungs by coughing...

Страница 3: ...0 minutes Lung expansion therapy expands the airways high frequency oscillation therapy mobilizes secretions and aerosol therapy delivers a medication deep into the lungs Alternating therapies of lung...

Страница 4: ...Cooling Fan Cools the main control board BACK PANEL 6 Power Switch Turns the control unit on and off 7 AC Power Inlet Connection port for the AC power cord to power the control unit and charge the ba...

Страница 5: ...rating mesh nebulizer for prescribed medication 6 Handset provides a comfortable grip for therapy delivery and a spacer for the nebulizer 7 Patient Interface there are three patient interface options...

Страница 6: ...ed You may have different therapy options as pre programmed therapies in the drop down list under Auto 4 Position the control unit on a firm flat surface within arm s length of the patient The control...

Страница 7: ...allows data transmission to Arc Connect and data time synchronization with the BiWaze Clear control unit s physicial location local time zone E Battery status F Date and Time G Pressure Manometer may...

Страница 8: ...thpiece during the therapy Flexible tracheostomy adapter if the patient has a tracheostomy tube or endotracheal tube use the flexible tracheostomy adapter to connect the tracheal tube to the breathing...

Страница 9: ...ustments on your system which allows changes to be made to the programmed therapy profiles while the device is locked If enabled therapy pressure can be adjusted up to 5 cmH20 per phase depending on w...

Страница 10: ...acterial filter coaxial breathing tube handset and patient interface 5 Examine the coaxial viral bacterial filter and discard if it is damaged by sputum or trapped moisture If it is not damaged gently...

Страница 11: ...ter with a mild detergent like liquid dish soap 5 Rinse thoroughly to remove all detergent residue 6 Reinstall the filter after it is completely dry Note Only Air Inlet Filters BC21274 from ABM Respir...

Страница 12: ...visit our webpage www abmrc com or call customer support 1 877 ABM RC01 877 226 7201 This Patient Guide contains information extracted from the BiWaze Clear user manual BK381 For complete instructions...

Отзывы: