17
1 Check the free movement of the door.
2 Turn mode switch to MAN.
The mode switch is located in the head panel.
3 Plug in the mains and turn the switch on.
The main switch is located in the head panel.
4 Choose the type of the arm.
Jumpers are located on the control board.
Jumper
is
connected.
Jumper
is
disconnected.
5 Choose the size of the door.
Jumper in block ”Custom” together with S, M or L gives you more power.
S + Custom, force between S and M.
M + Custom, force between M and L.
L + Custom, force more than L.
”Sealed” enables motorised closing pull before opening. Select this to ensure the proper
function of the lock when prepull is needed. Motorised closing will be activatd 20-40 mm
before the doors closed position.
6 Check the OPTION.
If the jumper is connected then operator requires N.C. output from the
fi
re detector.
If the jumper is disconnected then operator requires N.O. output from the
fi
re detector.
7 Safety sensor monitoring
Self diagnostics is in use when J2 (OS=opening side) and J3 (CS=closing side) are connected.
8 Oven auki- ja kiinniasennon opetus.
(toimii ohjelmakytkimen MAN ja AUTO tiloissa)
- Push TEACH-button to enter learning mode.
- Teach the door closed position:
Yellow led blinks: close the door and push TEACH-button.
- Teach the door open position:
Green led blinks: open the door to the desired angle and push
TEACH-button
.
- Yellow ”TEACH CLOSED” led blinks: close the door manually.
- The green light remains lit. Door open and closed position is taught.
9 COMMISSIONING
ARM
standard
sliding
not in use
not in use
not in use
sealed
custom
DOOR
not in use
not in use
not in use
sealed
custom
DOOR
OPTION
not in use
not in use
not in use
fi
re
n.c.
TEACH CLOSED
TEACH OPEN
POWER ON
TEACH
J1
J2
J3
J4
Содержание DA461