12 SELF
DIAGNOSTICS
Fault codes
- detect malfunctions
- to ensure safe operation where possible during malfunction
- to restore the operator to its required status
If the door operator is unrecoverable it will revert to manual operation only.
Both LED’s will blink.
Control units LED’s
TEACH CLOSED
TEACH OPEN
POWER ON
TEACH
Yellow led = Y
Green led = G
Corrective user interventions in de
fi
ned order
Indication
Possible fault
G not lit
Y not lit
No power.
Faulty power supply unit.
Faulty control board.
1) Check the mains.
2) Disconnect 9 pin connector from the control
board.
3) Measure the voltage of the power supply (5 pin
connector, pins 1 and 3). If voltage is under
24VDC, change the power supply unit.
4) Measure the voltage from 9 pin connector
(pins 9 and 8). If voltage is not 24VDC, change
the control board.
G lit
Y lit
The door ”close” and ”open”
positions are not successfully
taught.
Impulse device is active all the
time.
1) Teach the door open and close positions.
2) Check all impulse devices and connections.
G lit
Y
fl
ash
Flash short...short...short...:
1000 ohm resistor is missing or
cable of safety sensor is cut.
Flash short...long...short...long...:
Safety sensor is active or cable of
safety sensor is short-circuited.
1) Check that 1000 ohm resistor is connected in
control board or in safety sensor.
2) Check that cables are not damaged.
1) Move obstacle from safety sensor detection
area. If sensor sees the wall, adjust detection
area.
2) Check that cables are not damaged.
G
fl
ash
Y
fl
ash
Internal fault in the control board.
Door motion is stopped.
1) Switch main off for 10 seconds.
2) Check that all applicable jumpers are in place
(one of two arms is selected, one door size is
selected).
3) Teach the door open and close positions.
4) Change the control board.
G
fl
ash
Y
fl
ash
alternates
Internal fault in the position sensor
board.
Door motion is stopped.
1) Switch main off for 10 seconds.
2) Check that all applicable jumpers are in place
(one of two arms is selected, one door size is
selected).
3) Check position sensors cable and connector.
4) Teach the door positions.
5) Change the position sensor.
Содержание DA430
Страница 1: ...An ASSA ABLOY Group brand ABLOY DA430 SWING DOOR OPERATOR Installation and commissioning manual ...
Страница 4: ...4 1 REVISION Following pages have been revised Page Revision As at 21 09 2009 ...
Страница 20: ...20 COM N O N C 1 3 2 11 4 DA033 Elbow switch 11 5 DA039 and DA049 rotary switch red blue black ...
Страница 26: ...26 ...
Страница 27: ...27 ...