Net Weight (kg / lbs) 

17 / 37.5 

Gross Weight (kg / lbs) 

20 / 44 

Protection Class 

IP65, outdoor 

Cooling 

Convection 

AC Connection 

Connector 

DC Connection 

Multi-contact 

Communication   

 

Communication Interface 

Standard 

RS485 

Optional 

USB, Dry contact, TCP/IP, Wi-Fi 

Front Panel 

 

LCD   

mode   

2.90" LCD panel 

Solar panel voltage / Solar panel current / Solar panel power / AC output 
voltage / AC output frequency / AC output current / AC output power / yield / 
Inner Temperature / Heat sink Temperature / Status message / Error 
messages   

LED   

Green 

On: Energy generation by the solar panel is greater 

than the PV inverter's power in sleep mode 

Flashing: Energy generation by the solar panel is 

less than the PV inverter's power in sleep mode   

Yellow   

Power system quality abnormal 

Red   

PV inverter errors 

Key Pad 

UP key / Down key / Function key / Enter key 

Protection   

 

Utility 

Over /under Voltage, Over /under Frequency, 

Grounding fault, DC Isolation fault 

Islanding operation 

detection 

Passive : Voltage phase jump detection 

 

45

Active : Reactive power control 

Over Temperature 

Derating output power 

EPO   

The PV inverter powers off and stops its output and remains in standby mode 

Certification 

 

On-Grid Performance 

VDE0126-1-1/A1, VDE-AR-N 4105** 

Safety   

IEC 62109-1,-2 , IEC 60730-1

***

 

                        Model 

Item   

ES3000T  ES3680T  ES4000T  ES4600T  ES5000T 

ES5500T 

EMI/EMC 

EN 61000-6-2 
EN 61000-6-3 
EN 61000-3-2 
EN 61000-3-3 

EN 61000-6-2 
EN 61000-6-3 
EN 61000-3-11 
EN 61000-3-12 

EN 61000-6-2 
EN 61000-6-4 
EN 61000-3-11 
EN 61000-3-12 

Optional isolation transformers can be added if required. 

**  Models ES5000T / ES5500T de-rating to 4600VA for 

approved by VDE-AR-N 4105. 

***    PV modules must be have an IEC 60730-1 Class A rating. 

****  According  VDE-AR-N  4105  regulation,  if  we  want  to  built  a 

Power Generation Units, the maximum power for each phase 

can only reach to 4.6KW. 

 

 

Содержание EnerSolis ES3000T

Страница 1: ...9 2 3 Mounting the unit 11 2 4 Electrical Installation 13 2 5 Connecting to the Grid AC utility 16 2 6 PV Array Input Wiring 20 3 2 9 Panel 23 3 1 Functions of the 2 9 Panel 23 3 2 Display and Operati...

Страница 2: ...installation of the equipment 3 Safety Instructions Please read all the installation instructions in this EnerSolis user manual before installing or maintaining your system The PV inverter should be...

Страница 3: ...ld be repaired by trained electrical technicians only PV Array When installing and configuring the PV array make sure that the PV array s rated voltage parameters which provided by the manufacturer co...

Страница 4: ...ment Description 1 LCD panel and LED indicators Shows PV inverter operation information and status 2 DC input terminals The input connections of PV array 3 Standard communicationports RS485 EPO 4 Opti...

Страница 5: ...en selecting an installation location and method be sure to take the weight of the PV inverter into account An appropriate installation location will optimize system performance reduce the chances of...

Страница 6: ...tion Please see the diagram below for recommended heat dissipation space 20cm 20 cm 20 cm 20cm 5 cm 11 2 3Mounting the unit It is recommended to use the enclosed backplate to mount the PV inverter on...

Страница 7: ...ix holes Finally fix the backplate on the wall Step 2 Hang the PV inverter on the brackets Make sure the inverter holds firm and securely Inverter 13 Method II Use screws to fix the unit Step 1 As sho...

Страница 8: ...0A circuit breaker is recommended Make sure the DC circuit breaker has been installed between the PV inverter and the PV array Note The Ue 600Vdc Ie 20A circuit breaker is recommended The AC and DC ci...

Страница 9: ...e circuit breaker which connected to the utility is opened before installed the PV inverter s AC output The AC circuit breaker should be closed only after completed the electrical installation of the...

Страница 10: ...Figure 5 19 To prevent electric shock hazard make sure the ground of the PV inverter is connected to the ground properly before any operation Recommended wire diameter for AC cable Model Diameter mm A...

Страница 11: ...ange under any kind conditions 21 2 6 2 Installation steps for PV array input CAUTION An independent DC circuit breaker shall be installed between the inverter and the PV array before the PV inverter...

Страница 12: ...tring B It should be configured in the Setup Mode as shown in Figure 8 See Section 3 4 for details of the Setup Mode Figure 8 23 3 2 9 Panel 3 1 Functions of the 2 9 Panel Panel symbols described belo...

Страница 13: ...the value of PV inverter s sleeping power Buttons 5 Setup Query 6 Previous page 7 Next page 8 Confirm Setup changes 25 3 2 Display and Operation of 2 9 Panel Measurement Messages When the PV inverter...

Страница 14: ...put power as shown in Figure F 3 2 6 String B input power as shown in Figure G 3 2 7 Output voltage as shown in Figure H D E F G H 27 3 2 8 Output frequency as shown in Figure I 3 2 9 Output current a...

Страница 15: ...le when the total energy generation was 999 999 KWH as shown in Figures L1 and L2 3 2 13 The enclosure surface temperature can be displayed in Celsius or Fahrenheit as shown in Figures M1 and M2 M1 M2...

Страница 16: ...remains in standby mode It indicated by a flashing red LED Shutdown When PV array cannot generate enough energy such as at night or in rainy days the PV inverter will automatically shutdown to stop o...

Страница 17: ...lel mode as shown in FiguresP1 and P2 Note STD Standard Mode PAR Parallel Mode P1 P2 O1 O2 33 Step 4 Press the key to set the ID number of the PV inverter The panel now shows the SET and ID setting al...

Страница 18: ...ing PV inverter can be stopped immediately and remains in standby mode by shorting the circuit with the pins which specified in the right figure PIN 1 Reserve PIN 2 Reserve PIN 3 485 GND PIN 4 EPO GND...

Страница 19: ...e is too high or too low PIN 2 The input voltage for the maximum power tracker A or B is within the rated range PIN 3 The input voltage for the maximum power tracker A or B is too high or too low PIN...

Страница 20: ...US failed to reach the setting value 1 Disconnect the PV array from the PV inverter 2 Wait until the LCD monitor is completely off Then reconnect the PV array to the PV inverter 3 If the problems pers...

Страница 21: ...PV inverter s specifications 4 Restart the PV inverter If the problems persist please contact your local distributor AL01 Utility voltage too low AL02 Utility frequency too high Utility frequency is n...

Страница 22: ...inal AC Power 3000 VA 3680 VA 4000 VA 4600VA 5000VA 5500VA Nominal AC Voltage a c V AC 230V 43 Output Connect Method 1 Phase 2 Wire L N PE 1 Phase 3 Wire L1 L2 PE AC Voltage Rang a c A 184V 264 5V Bas...

Страница 23: ...ction key Enter key Protection Utility Over under Voltage Over under Frequency Grounding fault DC Isolation fault Islanding operation detection Passive Voltage phase jump detection 45 Active Reactive...

Страница 24: ...46 47...

Страница 25: ...48 49...

Отзывы: