ABL eMS home Скачать руководство пользователя страница 1

Article No.: 0301675_EN_a

Energy Management System

eMS home

User manual

EN

Содержание eMS home

Страница 1: ...Article No 0301675_EN_a Energy Management System eMS home User manual EN...

Страница 2: ...07 Lauf an der Pegnitz Germany 49 0 9123 188 0 49 0 9123 188 188 info abl de www ablmobility de Customer Service 49 0 9123 188 0 service abl de www ablmobility de de service support Revision 0301675_E...

Страница 3: ...onfiguration via the ABL Configuration Software 17 Starting up the eMS home 19 Starting the eMS home web interface 20 Structure of the web interface 21 Checking and updating the device firmware 22 Set...

Страница 4: ...Contents 4...

Страница 5: ...omputer tablet or smartphone Additional technical information is made available in the Portable Document Format PDF To display PDF files you need the free Adobe Acrobat Reader or comparable software Y...

Страница 6: ...h this symbol must be carried out with special care NOTE Indicates important information for operation or installation Sections marked with this symbol indicate further important information and featu...

Страница 7: ...e eMS home and another supplied in the package are used for identification purposes The rating plate contains the following important information Serial number MAC address Factory assigned password fo...

Страница 8: ...Number Designation 1 Outer conductor L1 L2 L3 outputs 2 RS485 A connection 3 RS485 B connection 4 2 LAN connection 5 Neutral conductor N 6 Outer conductor L1 L2 L3 inputs 7 Reset button 8 Serial bus...

Страница 9: ...ection on Data cable recommendations on page 49 Requirement for cable installation In the area for connecting the RS485 interfaces on the eMS home mechanical means must be provided to ensure that indi...

Страница 10: ...ly the phase rotation must be set up according to the following diagram when installing the wallboxes Wallbox eMH1 1 eMH1 2 eMH1 3 eMH1 4 eMH1 5 eMH1 6 RCD terminals L3 L2 L1 N L3 L2 L1 N L3 L2 L1 N L...

Страница 11: ...ple for implementation 2 Connect the conductors to the eMS home y Pay attention to the permissible connection cross section and the tightening torque for the screw terminal see Technical specification...

Страница 12: ...echnical specifi cations on page 48 4 Connect the connecting cables for the current meas urement to the eMS home see also box below y Pay attention to the permissible tightening torque for the screw t...

Страница 13: ...ation via the ABL Configuration Software on page 17 onwards Communication between the eMS home and the eMH1 Wallboxes is via CAT5e or equivalent data lines which must comply with the specifications in...

Страница 14: ...Pin B Pin 2 Pin M Bus wiring via E2I interface For bus wiring via the E2I interfaces for products manufactured from mid 2021 the following generally applies The data line is connected to the internal...

Страница 15: ...spring terminal which is not connected to the data lines between terminals A and B of evcc rfid A M B evcc rfid A M B meter A M B meter Termination of a wallbox with E2I interface eM1 from mid 2021 Co...

Страница 16: ...ibed in the section Prepar ing and mounting the wallbox in the installation instructions for the eMH1 Wallbox 2 Connect the patch cable 3 to the spring terminals located on the left hand side of the i...

Страница 17: ...by cable ABL Configuration Software 1 2 5 Configuration via the ABL Configuration Software After you have set up the cabling between the wallbox es and the computer you can start configuring the wallb...

Страница 18: ...the left hand field in this example 3 9 Now enter the new destination address for the charg ing station in the right hand field in this example 6 10 Now click the Address manually button y The new add...

Страница 19: ...and lock all eMH1 Wallboxes in the system 2 Switch off the house connection 3 Insert the RS485 connector into the connector socket B on the top of the eMS home y Make sure the data lines are also sti...

Страница 20: ...home Enter the IP address of the eMS home in the address bar of the web browser to open the login window If a DHCP server is active in the network you can check in the configuration interface of the...

Страница 21: ...bar is static and is always displayed 2 Use this button to show or hide the sidebar 3 Use this button to display all system messages 4 Use this button to select the language for the web interface 5 Us...

Страница 22: ...e Service All downloads Software Firmware eMS home section and is installed via the eMS home web interface Proceed as follows 1 Click the Device settings button at the bottom of the web interface y Th...

Страница 23: ...d after a period of about 5 minutes the eMS home may have received a new IP address Proceed as described in the section Log in to the eMS home on page 20 to open the web interface manually Setup via t...

Страница 24: ...the option ABL charging station and click the Add button y The Add ABL charging station page then opens 8 Enter the required information about the connected wallbox on the Add ABL charging station pa...

Страница 25: ...home is set up correctly Finally click on the arrow on the right to exit the Settings and return to the Wallbox app NOTE Internal processing of settings When you exit the Settings menu an error messa...

Страница 26: ...ow represents the power being drawn while the lower arrow represents the power being fed in The current state is indicated by a green dashed arrow in the illustration above the system is currently dra...

Страница 27: ...played Information Only messages from the Information category are displayed The current selection is indicated by a green bar The table below shows the timestamp of the message the app that sent the...

Страница 28: ...ort 1 once the email settings have been configured in the Device settings see chapter Device settings app on page 39 The recipient s Email address 2 is displayed at this point for information only Cli...

Страница 29: ...g in power The Active energy 2 widget shows the ratio of active energy between the three phases The drop down list 3 can be used to switch between the Consumption and Feed in display The table in the...

Страница 30: ...rging process are displayed Charging process paused The charging process has been stopped In the graphic the vehicle is con nected to the charging device The charger contains a pause symbol and the en...

Страница 31: ...d on the connected vehicle and are determined during the initialisa tion phase Charged energy indicates how much energy in kWh has already been charged during the current charging process Charging cur...

Страница 32: ...er of all configured charging devices is shown in kW and also as a colour ed bar on a grey background The red line on the bar graph shows the maximum available power given to the charging devices The...

Страница 33: ...device is displayed here by means of the following states The OK tick symbol indicates that communication with the charging device is working properly The Error symbol indicates that communication wit...

Страница 34: ...rompt to confirm whether you really want to delete the charging device Click Yes to delete the charging device Click No to close the window without deleting the charging device View details of an ABL...

Страница 35: ...no guaranteed protection against overload of the main fuse Data store app Description The Data store app allows for continuous storage and display of all the energy and performance values of the eMS h...

Страница 36: ...herefore first be selected in order to read the measured values of the sensor The values of the other phases and the total values are empty Period The daily values of the set month or the monthly valu...

Страница 37: ...g specifications Selected period Selectable resolution of the value intervals 1 day 1 minute 15 minutes 1 day 14 days 15 minutes 1 day 14 days 1 day After making your selection the download can be sta...

Страница 38: ...inute 15 minutes day Week 15 minutes day Month Day Year Day In addition a Start date 2 can be selected for the start of the automatic export If necessary the exported data can be compressed as a ZIP f...

Страница 39: ...Clicking on the Edit button opens the corresponding widget in the Device Settings app As an additional option you can specify a Subject 0 for the email The default is Energy Manager Automatic Export D...

Страница 40: ...duct name Installed firmware version Serial number of the eMS home Current CPU load Current CPU temperature Current RAM usage Used space of the app partition Used space of the data partition Host name...

Страница 41: ...letters numbers and hyphens When DHCP 2 is enabled the eMS home automatically obtains an IP address for example from a router No fur ther settings are necessary If a static IP address is to be set DHC...

Страница 42: ...ort FTP server port Username Username for logging in to the FTP server The username must contain at least 3 letters Password Password for logging in to the FTP server Click on SAVE 2 to save the setti...

Страница 43: ...server requires authenti cation option is activated Password Password for logging in to the SMTP server Only necessary if the The server requires authentica tion option is activated Click on SAVE 2 t...

Страница 44: ...re displayed correctly after importing into Microsoft Excel External current transformer The eMS home can directly measure up to 63 A per phase conductor External current transformers are required for...

Страница 45: ...ocess is started by clicking CREATE 1 After the backup process has been completed a backup file Backup bak is made available to download in the browser Import a backup To import a backup a local backu...

Страница 46: ...for the system NTP If the system is permanently connected to the Internet via the network it is recommended to activate the NTP option This automatically obtains the time from the Internet via a serv...

Страница 47: ...do this first select the update file and then click UPDATE After a confirmation prompt the new firmware is uploaded installed and the eMS home is restarted This process may take several minutes The we...

Страница 48: ...ative humidity non condensing Up to 75 as an annual average up to 95 on up to 30 days year Max altitude during operation 2000 m above sea level Mains power supply Starting current 25 mA Supply voltage...

Страница 49: ...lines within the group installation must not exceed 100 m PIN allocation within the system eMH1 with spring terminal eMS home eMH1 with RJ45 connector Conductor colour Top view of terminal ABL bus al...

Страница 50: ...utton 1 as follows y 1 long between 3 and 5 seconds y then within 1 s 1 short 0 5 second If the command was recognised correctly the Status LED 2 flashes orange twice The password for the web interfac...

Страница 51: ...ess again 101 An error occurred while creating a backup or importing a backup file Please check your settings and try importing exporting the backup file again If the error persists please create the...

Страница 52: ...e with the firm ware used under Device Settings System information If the product specifications differ you will need firmware that is compatible with the device If the error persists please create th...

Страница 53: ...rror description and remedy 500 The error End of service life of flash memory cannot be resolved by the user Please contact Customer Service OBIS system of indicators OBIS codes are used for data tran...

Страница 54: ...mps and smart meters Description OBIS code Unit Timestamp YYYY MM DD HH MM SS UNIX timestamp Active Power 1 0 1 4 0 255 W Active Power min 1 0 1 3 0 255 W Active Power max 1 0 1 6 0 255 W Active energ...

Страница 55: ...Active energy L1 1 0 22 8 0 255 Wh Reactive power L1 1 0 23 4 0 255 var Reactive power L1 min 1 0 23 3 0 255 var Reactive power L1 max 1 0 23 6 0 255 var Reactive energy L1 1 0 23 8 0 255 varh Reactiv...

Страница 56: ...ar Reactive power L2 min 1 0 43 3 0 255 var Reactive power L2 max 1 0 43 6 0 255 var Reactive energy L2 1 0 43 8 0 255 varh Reactive power L2 1 0 44 4 0 255 var Reactive power L2 min 1 0 44 3 0 255 va...

Страница 57: ...e power L3 max 1 0 63 6 0 255 var Reactive energy L3 1 0 63 8 0 255 varh Reactive power L3 1 0 64 4 0 255 var Reactive power L3 min 1 0 64 3 0 255 var Reactive power L3 max 1 0 64 6 0 255 var Reactive...

Страница 58: ...Depending on the number of phases used to charge the vehicle this summed surplus is divided arithmetically among the phases of the connected vehicle Example A single phase charging vehicle is charged...

Страница 59: ...ellectual property copyright Copyright 2022 Version 0301675_a Last updated 21 January 2022 Software version 3 0 0 All rights reserved Any information contained in this manual may be changed without pr...

Страница 60: ...MADE IN GERMANY ABL GmbH Albert Bu ttner Stra e 11 91207 Lauf an der Pegnitz Germany 49 0 9123 188 0 49 0 9123 188 188 info abl de www ablmobility de...

Отзывы: