![ABL eMH3 Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/abl/emh3/emh3_installation-manual_452110048.webp)
| Error resolution and maintenance –
Identifying errors
48
Error F6 (variants with charging socket only)
Description
Flash pattern
Per cycle, the green battery icon flashes twice,
followed by the blue power symbol flashing
twice.
The red warning symbol remains ON.
Cause
Suggested solution
The charging cable's current rating is incorrect.
The wallbox automatically reinitiates the charging proce-
dure every 60 seconds. Should the error occur again, check
the position of the plug in the charging socket, or unplug it
and plug it back in.
Should the error persist, take the wallbox out of operation
(see page 53) and contact a qualified specialist electrical
contractor to resolve the error.
Error F7
Description
Flash pattern
The blue power symbol flashes twice per cycle
while the green battery icon remains OFF.
The red warning symbol remains ON.
Cause
Suggested solution
The vehicle demands a charging procedure with
ventilation.
The wallbox does not support charging procedures with
ventilation.
Error F8
Description
Flash pattern
The green battery icon flashes twice per cycle
while the blue power symbol remains OFF.
The red warning symbol remains ON.
Cause
Suggested solution
A short circuit has been detected between
the pilot contact CP and the protective earth
PE.
The vehicle's communication interface is
faulty.
The wallbox automatically reinitiates the charging proce-
dure every 60 seconds.
If the error persists, check the charging cable and/or the
charging socket of the wallbox. If you detect any damage,
take the wallbox out of operation and contact the dealer
from whom you have purchased the wallbox.
If no damage is detected when checking the charging cable
and socket, the vehicle must be checked: please contact a
qualified specialist repairer.