ABL 1V0002 Скачать руководство пользователя страница 2

2

[email protected]

www.ablmobility.de

Albert-Büttner-Straße 11

D-91207 Lauf / Pegnitz

Phone  +49 (0) 9123 188-0

Fax  +49 (0) 9123 188-188

ABL SURSUM

Bayerische Elektrozubehör GmbH & Co. KG

Connecting master/slave communications and commissioning

Tools and materials required:

 M32 cable gland with strain relief, cable cutters, wire stripper, data cable (twist-

ed pair, at least CAT5 or above), Pozidriv screwdriver, Voltmeter

The circuit breaker in the domestic power distribution must remain switched off until step 

5

.

Cut the data cable to the required length for connecting to the daisy chain circuit board and strip as required (tools: 

cable cutter, wire stripper).

Strip the wire strands of the data cable.

Clamp the wires of the data cable onto the left or right hand side terminal block of the daisy chain circuit board.

Wire strand colour*  
(recommended)

Connection coding

Description

White-Orange

METER – B

DATA energy meter

Orange

METER – M

GND energy meter

White-Green

METER – A

DATA energy meter

Green

CONTROL – B

DATA control unit

White-Blue

CONTROL – M

GND control unit

Blue

CONTROL – A

DATA control unit

* Colour coding according to EIA/TIA-T568B, variations possible

Insert the data cable into the first Slave wallbox and clamp in onto the left or right hand side terminal block of its 

daisy chain circuit board (see the detailed installation and operating manual for the wallbox).

For correct functioning, the colour coding between the individual data cable wire strands and the daisy chain 

terminal blocks must be strictly observed in all master/slave units!

Only the first Slave wallbox will be connected directly to the 1V0002. Each additional slave will be connect-

ed to the Slave wallbox that precedes it.

Switch on the circuit breaker for the power supply to the 1V0002 in the domestic power distribution and measure 

the voltage at the RCCB if required (tool: voltmeter).

Flip the pivot levers of the internal MCB and RCCB to the 

I

 position.

This completes the commissioning of the 1V0002 control unit.

Setting up master/slave communications

Tools and materials required:

 Computer, Ethernet cables with RJ45 plug-in connectors

In order to proceed with configuration, the 1V0002 must be connected to the power supply. Special caution 

is therefore required due to the presence of electrical voltages!

Use the Ethernet cable to connect the computer to the RJ45 socket on the centrally located SBC circuit board of the 

1V0002.

On the computer, open the browser and enter the address http://169.254.1.1:8300/.

All manuals and user guides at all-guides.com

Содержание 1V0002

Страница 1: ...tractor Mechanical and electrical installation During the installation the circuit breaker for the supply line must be switched off in the house distribution Tools and materials required Pozidriv screwdriver wire stripper crimping tool 1 Attach the 1V0002 control unit using the DIN rail at the chosen installation site 2 Strip the wires of the supply line put ferrules on the wires and crimp on the ...

Страница 2: ...ble into the first Slave wallbox and clamp in onto the left or right hand side terminal block of its daisy chain circuit board see the detailed installation and operating manual for the wallbox For correct functioning the colour coding between the individual data cable wire strands and the daisy chain terminal blocks must be strictly observed in all master slave units Only the first Slave wallbox ...

Страница 3: ...r Assigning backend ID to control unit Devices Checking the system s total connected load Checking the maximum connected load for each Slave wallbox Products Registering additional Slave wallboxes in the system Editing 1V0002 properties Certificates Checking backend operator certificates Diagnostic Functions Checking version and status information for all communicating components in the system Log...

Страница 4: ...abl de www ablmobility de Albert Büttner Straße 11 D 91207 Lauf Pegnitz Phone 49 0 9123 188 0 Fax 49 0 9123 188 188 ABL SURSUM Bayerische Elektrozubehör GmbH Co KG All manuals and user guides at all guides com ...

Отзывы: