In case of connection errors, check the network settings of the computer and adjust them as follows:
• Network: 169.254.0.0
• Subnet mask:
255.255.0.0
• Address: 169.254.1.2
4
The online administration interface opens in the browser. The following functions are available using the tabs:
Tab
Description
Overview
• Checking the status of all recognised master and slave model variants
• Checking the system software version
Configuration
• Checking information about the 1V0001 control unit, the backend and OCPP
• Editing backend operator details (only when changing backend operator)
• Assigning backend ID to control unit
Devices
• Checking the system's total connected load
• Checking the maximum connected load for each Slave wallbox
Products
• Registering additional Slave wallboxes in the system
• Editing 1V0001 properties
Certificates
• Checking backend operator certificates
Diagnostic
Functions
• Checking version and status information for all communicating components in the
system
Logs
• Checking logged access to the communicating components in the system
Maintenance
• Carrying out a restart (software and/or hardware)
• Updating the system software
• Running system diagnostics
A complete description of the configuration process is available in the detailed installation and operating
manuals for the 1V0001 control unit.
5
Disconnect the Ethernet cable from the RJ45 sockets in both the 1V0001 and the computer.
6
Flip the housing cover up and fix it hand-tight onto the housing base with the screws (4 screws,
→
master/slave communications”, step 1) kept aside for this purpose (tool: Pozidriv screwdriver).
The 1V0001 control unit is now configured as master to control the Slave wallboxes.