background image

[email protected]

www.ablmobility.de

Albert-Büttner-Straße 11

D-91207 Lauf / Pegnitz

Phone  +49 (0) 9123 188-0

Fax  +49 (0) 9123 188-188

ABL SURSUM

Bayerische Elektrozubehör GmbH & Co. KG

3

Wire strand colour*  
(recommended)

Connection coding

Description

White-Orange

METER – B

DATA energy meter

Orange

METER – M

GND energy meter

White-Green

METER – A

DATA energy meter

Green

CONTROL – B

DATA control unit

White-Blue

CONTROL – M

GND control unit

Blue

CONTROL – A

DATA control unit

* Colour coding according to EIA/TIA-T568B, variations possible

Insert the data cable into the first extender wallbox and clamp in onto the left or right hand side terminal block of 

its daisy chain circuit board (see the detailed installation and operating manual for the wallbox).

For correct functioning, the colour coding between the individual data cable wire strands and the daisy chain 

terminal blocks must be strictly observed in all controller/extender units!

Only the first extender wallbox will be connected directly to the 1V0001. Each additional extender will be 

connected to the extender wallbox that precedes it.

Switch on the circuit breaker for the power supply to the 1V0001 in the domestic power distribution and measure 

the voltage at the RCCB if required (tool: voltmeter).

Flip the housing cover up and fix it hand-tight onto the housing base with the screws (4 screws, 

 “Installing and 

connecting the 1V0001”, step 5) kept aside for this purpose (tool: Pozidriv screwdriver).

Loosen the knurled screw on the housing cover and open the cover flap.

10 

Flip the pivot levers of the internal MCB and RCCB to the 

I

 position.

11 

Close the cover flap and secure it using the knurled screw.

This completes the commissioning of the 1V0001 control unit.

Setting up controller/extender communications

Tools and materials required:

 Pozidriv screwdriver, computer, Ethernet cables with RJ45 plug-in connectors

In order to proceed with configuration, the 1V0001 must be connected to the power supply and the cover flap 

must be open. Special caution is therefore required due to the presence of electrical voltages!

Remove the 4 Phillips head screws in the corners of the housing cover and flip back the housing cover. Keep the 

screws in a safe place (tool: Pozidriv screwdriver).

Use the Ethernet cable to connect the computer to the RJ45 socket on the centrally located SBC circuit board of the 

1V0001.

The SBC circuit board is centrally located in the middle of the housing base.

On the computer, open the browser and enter the address http://169.254.1.1:8300/.