background image

 110406_ABI-EV1002_QSG_ML.doc 

English  

   Page 

N.V.

 abitana 

S.A.

 

ENGLISH

 

 

ABI-EV1002S00 

Twisted Pair Broadband 

Distribution Amplifier

 

Quick Start Guide 

 

 Package Contents 

 

DIN rail mountable Broadband Amplifier module 

 

Quick Start Guide 

 3 

Termination 

plugs 

ABI-AP1003S00 

 

Power jumper cord ABI-PS1001SPC 

2 Tools 

 Level 

tester 

ABI-TT1003S12 

 Spanner 

11mm 

 

Flat screw driver max. 5mm x 0.6mm 

3 Introduction 

The ABI-EV1002S00 is a Broadband Amplifier with one coaxial 
input for CATV signal or antenna. 

The unit has 4 independent RJ45 (Twisted Pair) outputs on the 
front. 

For ease of installation, a Power Level indicator is provided, 
indicating the safe area of operation for optimal transmission and 
quality results. 

A range of Twisted Pair to Coax adapters (with or without 
adjustment, filters,…) is available for installation at the receiver 
end (i.e. ABI-AC1001S00*). 

It is possible to connect a Radio by using a Radio adapter (ABI-
AC1004S00) or an adaptor without filter. 

4 Connectors 

  

P1

 

P2

 

P3

 

 

 

POWER

 

P4

Input to CATV signa l

or Antenna

Outputs to 4 indepent

TV Sets

Power Adjustment

Grounding wire

 

ABI-EV1002S00 

Power level a djustment

 

(ABI-AC1001S00) 

 

 

5 Power 

Load ratio for this module = 0,5. 

Maximum allowed load ratio (sum of the load ratios for all modules) for 
power supply ABI-PS1001S11 = 4. 

6 Installation 

 

 

Power Off the central 

ABI-PS1001S11

 Power Supply by means of the 

Circuit Breaker installed in the ‘

Comm Center Cabinet

’, or by 

removing the mains power cord from the Power Supply. 

 

1. 

Make sure the shielding of the Network Interface Unit (NIU) 
or CATV transition point is properly connected to the 
protective ground. 

2. 

Open the ‘Comm Center Cabinet’ 

3. 

Click the ABI-EV1002S00 unit on the metal DIN-rail. 

4.  The ABI-EV1002S00 is supplied with a grounding wire, 

connected to the input F-connector. 

This wire (1) must be connected to the protective ground of 
the installation. 

The following system devices also need to be connected to 
the protective ground: The DIN-Rail frame (2) and the Power 
supply (3) 

 

EV1002

Power

Supply

DIN-Rail Frame

PE1002

1

2

3

4

DC1015

 

5.  Provide power to the module using the included power 

jumper cord ABI-PS1001SPC. Please consult the manual of 
the power supply for more information concerning the 
installation of the power supply. 

6. 

Connect a coax cable from the CATV connection point (NIU) 
or the CATV transition point to the coax connector on the top 
of the unit. 

 

Failing to follow the instructions (1) to (6) in the specified order 
may lead to permanent damage of the ABI-EV1002S00 amplifier 

 

When it is impossible to connect the DIN rails ,frame or CATV 
transition point to ground, make sure they are at least at the same 
electrical level (connected to each other). 