8 Maintenance and cleaning
EN
-
13
1
Remove weld spatter.
2
Check that all threaded fittings are tight.
8.1 Cleaning the wire guide
1
Unscrew the cable assembly on the machine side and lay it out straight.
2
Unscrew the nut and pull out the liner.
3
Clean the wire conduit from both sides with compressed air.
4
Slide the adjusted liner into the wire conduit and secure with a nut.
8.2 Mounting and shortening the liner
New and unused liners must be shortened to the actual length of the cable assembly.
1
Lay out the cable assembly
2
Disconnect the central connector
from the feed unit.
3
Screw on the retaining sleeve
4
Replace the old liner
with a new one and insert the stripped side into the central connector
.
5
Place the retaining sleeve
inverted by 180 ° onto the new liner
WARNING
Electric shock due to defective cables
Damaged or improperly installed cables can lead to fatal electric shock.
► Check all live cables and connections for proper installation and damage.
► Damaged, deformed or worn parts should only be replaced by a qualified electrician.
WARNING
Risk of injury caused by parts swirling around
The use of compressed air for cleaning purposes can cause device parts to come loose and cause
serious injuries.
► When cleaning the wire guide with air, wear suitable protective clothing, in particular safety goggles.
Fig. 5
Mounting and shortening the liner
A
Retaining sleeve
B
Central connector
C
Cable assembly
D
Nut
E
Liner
F
Collet
A
D
B
C
F
E