![background image](http://html1.mh-extra.com/html/abicor-binzel/sr-abitig-grip/sr-abitig-grip_operating-instructions-manual_451523018.webp)
EN - 6
BAL.0047 • 2018-09-11
3 Product description
SR/ABITIG
®
GRIP
All data refer to 4 m hose assemblies. For any further information regarding the available hose
assembly designs and performance data, please refer to the order documentation.
Type
Type of
cooling
Load
ED
Electrode ø
Gas
flow
Cooling Torch
inlet
pressure
DC
AC*
Max.
supply
temp.
Min.
flow
min.
max.
A
A
%
mm
l/min
°C
l/min
bar
bar
SR/ABITIG
®
GRIP
24 G
air
110
80
35
0,5 - 1,6
5 - 12
24 W
liquid
140
100
100
0,5 - 2,4
7 - 15
50
0.7
2.5
3.5
ABITIG
®
GRIP
12-1
liquid
400
280
100
1,6 - 4,0
7 - 20
50
0.8
2.5
3.5
18 SC
liquid
400
280
100
0,5 - 4,8
7 - 20
50
0.8
2.5
3.5
SR/ABITIG
®
GRIP
9
air
110
80
35
0,5 - 1,6
5 - 12
17
air
140
100
35
0,5 - 2,4
7 - 15
26
air
180
130
35
0,5 - 4,0
7 - 18
18
liquid
320
230
100
0,5 - 4,0
7 - 20
50
0.8
2.5
3.5
20
liquid
240
170
100
0,5 - 3,2
8 - 20
50
0.7
2.5
3.5
20 SC
liquid
320
220
100
0,5 - 3,2
8 - 20
50
0.7
2.5
3.5
SR (handle tube)
20
liquid
220
150
100
0,5 - 3,2
8 - 20
50
0.7
2.5
3.5
Tab. 4
Product-specific torch data (EN 60 974-7)
*According to EN 60 974-7 the value for alternating current (AC) must be given at 70% of the tested direct
current value (DC).
Liquid-cooled torches
min. 800 W
Tab. 5
Required cooling unit capacity