6 Putting into operation
iFEED 742
6 Putting into operation
6.1 Connecting the intermediate cable assembly
The device is connected to the welding power source via the intermediate cable assembly.
1
Connect both control leads to connectors
and
and to the power source.
2
Connect the wire feed hose to connection
3
Connect the compressed air hose to the compressed air connection
.
4
Connect the compressed air-hose to the compressed air supply.
5
Connect the shielding gas hose to the shielding gas connection
6
Connect the shielding gas hose to the decompression valve or the shielding gas supply line and check
for leaks.
Fig. 3
Connecting the intermediate cable assembly to the device
A
Welding torch control lead connection
B
Wire feed hose connection
C
MPP control lead connection
D
Compressed air connection
E
Shielding gas connection
NOTICE
Material damage due to loose connection
If the welding power cable connection is loose, increased contact resistance occurs and thus
impermissible heating at the connection. The welding process can be negatively influenced.
► Ensure the secure seating of the welding power cable.
Fig. 4
Connecting the welding power cable
F
RPC connection
G
Welding power cable
H
Washer
I
Lock washer
J
Hexagon bolt M10 × 16
K
Slot for welding power cable
D
E
C
A
B
K
F
J
G
H
I