BRS-LC
7 Transport and installation
BAL.0030 • 2019-01-18
EN - 13
7.6 Setting up the compressed-air motor
also Fig. 4 Putting into operation on page EN-11
1
Loosen the compressed-air motor from the guide block
2
Pull back the compressed-air motor
in its fastener.
3
Place the required distance sleeve
on the reamer
.
4
Move the torch with the gas nozzle
to the clamping position (P2).
5
Keep the guide block
in the lower position (stroke down).
6
Place the compressed-air motor
against the gas nozzle
with the distance sleeve placed on top
7
Fasten the adjusted motor position by means of the screws
.
8
Move the torch out the clamping device
and remove the distance sleeve
.
NOTICE
• When changing the reamer, only use tools with a suitable width across flats.
Motor protection cap AF 21, reamer AF17.
1
Clamping device
2
Gas nozzle
3
Screws
4
Guide block
5
Compressed-air motor
6
reamer
7
Distance sleeve
Fig. 8