EN - 14
6 Putting into operation
ADF 600S
2
Turn the controller
to the necessary protection level. The tip of the arrow indicates the adjusted
protection level.
6.4.2 Selecting the Grind protection level
Fig. 8 Protection levels on page EN-13
As soon as the "Grind" protection level is set, the protective function for the welding is switched off and
allows for a clear view for grinding a welded piece. The
ADF 600S
is thus used to protect the face.
1
Turn the controller
to the GRIND position
.
2
Grind the welded piece.
3
Finish grinding and turn the controller
to the corresponding protection level for the welding process.
6.5 Adjusting the light sensitivity (SENSITIVITY)
1
to the desired LOW or HIGH light sensitivity.
6.6 Adjusting the DELAY TIME
Fig. 9 Adjusting the light sensitivity / delay on page EN-14
As soon as the welding is stopped, the automatic filter switches from dark to light.
The pre-set delay time compensates for the after glow on the workpiece after welding.
1
to the desired SLOW or FAST delay time.
1
Light sensitivity (SENSITIVITY) switch
2
Delay time (DELAYTIME)
Fig. 9
Adjusting the light sensitivity / delay
1
2
NOTICE
• HIGH setting suitable for:
daily use
• LOW setting suitable for:
low current range, TIG welding, excessive ambient light or for a different welding machine in the
direct proximity
NOTICE
• FAST setting from 0.25 to 0.3 sec suitable for:
spot welding
• SLOW setting from 0.65 to 0.8 sec suitable for:
welding in high-amp range, TIG welding in low current range