6 Putting out of operation
1
Open the shielding gas cylinder.
2
Start the welding process.
3
After ignition, hold the welding arc tight to the edge of the material to be
welded until a molten pool is formed.
4
Move the torch uniformly over the entire seam length.
5
Stop the welding process.
6
After switching off, hold the torch over the end position for a few seconds.
This allows the molten pool to solidify without atmospheric interference
under the protection of the gas which is continuing to flow.
6 Putting out of operation
1
Switch off power supply.
2
Close the valve of the shielding gas cylinder.
7 Maintenance and cleaning
WARNING
Electric shock
Equipment parts are energized in the enterprise.
• Do not reach into the danger zone.
DANGER
Risk of injury due to unexpected start-up.
For the entire duration of maintenance, servicing, dismounting and repair
work, the following instructions must be adhered to:
• Switch off the power supply.
• Cut off the gas supply.
• Pull the mains plug.
DANGER
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation.
• Replace any damaged, deformed or worn parts.