EN - 16
10 Troubleshooting
ABIROB
®
A
3
Check wearing parts for visible damage and replace them, if required.
4
Replace equipment kit when worn or soiled.
5
Clean separating point and O-rings with silicone-free sealing grease.
6
Check the TCP after each use or after a collision in the WH setup device.
10 Troubleshooting
NOTE
• Some problems are listed below, with descriptions of possible causes
and solutions. If the measures described below are not successful, please
consult your dealer or the manufacturer.
• Please also consult the operating instructions for the welding
components, such as power supply, air pressure line.
Problem
Cause
Solution
Torch necks gets hot • Contact tip not tightened
• Contact tip loose on the neck side
and toward the work-piece
• Check and tighten
• Check and tighten
No push-button
function
• Control line interrupted / defective
• Check/repair
Wire burned solid in
the contact tip
• Wrong parameters set
• Contact tip worn out
• Check or correct setting
• Replace
Irregular wire feed
• Guide spiral liner/PA liner clogged
• Contact tip and wire diameter not
matched
• Wrong contact pressure set on the
wire feed unit
• Clean both directions with
compressed or replace it, if necessary
• Replace contact tip
• Correct as specified by manufacturer
Arc between gas
nozzle and work-
piece
• Spatter bridge between contact tip
and gas nozzle
• Clean and spray gas nozzle interior
Unsettled arc
• Contact tip not matched to the wire
diameter or contact tip diameter
enlarged
• Wrong welding parameters set
• Wire guide unit worn-out
• Check contact tip
• Correct welding parameters
• Replace wire guide unit
Tab. 8