background image

S O L A  O U T D O O R   S H O W E R   S E T

D is c la imer:  P ro d u c ts  in  th is  ma n u a l mu s t b y  la w  b e in s ta lled  b y  lic en s ed  a n d  reg is tered  tra d es p eo p le in  a c c o rd a n c e w ith  th e relev a n t s ta n d a rd s .  A B I  a n d  th e ma n u f a c tu rer/d is trib u to r

res erv e th e rig h t to  v a ry  s p ec if ic a tio n s  o r d elete mo d els  f ro m th eir ra n g e w ith o u t p rio r n o tif ic a tio n .  D imen s io n s  a re n o min a l mea s u remen ts  o n ly .  Th e in f o rma tio n  lis ted  is  c o rrec t a t th e time

o f  p u b lic a tio n ,  h o w ev er A B I  a n d  th e ma n u f a c tu rer/d is trib u to r ta k es  n o  res p o n s ib ility  f o r p rin tin g  erro rs .  C o p y rig h t © A B I  I n terio rs  2 02 2  P ty  Ltd

SPECIF ICATIONS

RECOMMENDED USE

Domest ic

MATERIAL

31 6 St ain less St eel

TEMPERATURE RATING

Maximu m con t in u ou s workin g t emperat u re 7 5°C
If t h e wat er t emperat u re exceeds 7 5°C,an  approved t emperin g
valve mu st  be fit t ed

PRESSURE RATING

Recommen ded min imu m workin g pressu re 1 50kPa
Recommen ded maximu m workin g pressu re 500kPa
H ot  an d cold wat er in let  pressu re sh ou ld be equ al

SUITABLE HOT WATER UNITS

St orage t an k: Yes
Con t in u ou s Flow: Yes
Gravit y Feed: Not  su it able

STANDARDS

O verh ead Sh ower: WELS 3 st ar, 9L/min , H an d Sh ower: WELS 3 st ar,
8 .5L/min , S1 6553

AS/NZS 3718 : 2005

WM-021226

Содержание SOLA 13329

Страница 1: ...tio n h o w ever A B I a n d th e ma n u f a ctu rer d is trib u to r ta kes n o res p o n s ib ility f o r p rin tin g erro rs C o p yrig h t A B I I n terio rs 2 02 2 P ty Ltd SPECIFICATIONS RECOMMENDED USE Domestic MATERIAL 316 Stainless Steel TEMPERATURE RATING Maximum continuous working temperature 75 C If the water temperature exceeds 75 C an approved tempering valve must be fitted PRESSURE ...

Страница 2: ...to commencing any works to determine the most appropriate method for you Please note this product must not be installed encased in concrete to allow access to water connections See examples of correct installation methods below ABI s warranty is void if this product is installed incorrectly or encased in concrete Installation on top of concrete slab with timber decking Th is ins t allat io n in s ...

Страница 3: ...ot and cold water pipes use appropriate thread sealant 3 5 Attach and bolt body to base 6 1 Trim plastic housing to be level with floor structure if required 2 Secure water pipes appropriately 4 1 Remove base drill the holes into the concrete footing to a depth of 60mm 2 Insert dyna bolts CONCRETE FOOTING 2 1 1 1 1 2 2 2 Hot Cold 2 60 Connect shower head to Arm ...

Страница 4: ...h cover plate down 7 1 1 1 2 8 Connect Arm to Body 1 Connect internal flexi hoses 2 Push together and use an alan key to fasten set screw Test and check all water points for leaks 9 1 Attach hand held shower head 2 Test and commission ...

Страница 5: ... held Shower Head 8 Hose 9 Set Screw 10 20mm Bolt 11 90mm Dyna Bolt set 12 Alan key 6mm 13 Alan key 3mm x6 x10 DO NOT use cream cleaners or bleach These substances are abrasive Regularly clean with mild liquid detergent or soap and water DO NOT use cleaning pads with abrasive surfaces as this may scratch the material ...

Отзывы: