2100 ELECTROMAGNETIC DOOR HOLDER, RECESSED, WALL MOUNT

1" Extension

*

*

Lock Edge

of Door

Approx.

2-5/8"

2-5/8"

1"

WALL PORTION INSTALLATION:

1. Measure distance from pivot centerline to wall (Dim. "A").

2. Determine door width (Dim. "B").
3. Use table below to locate magnet box on wall (Dim. "C").
    a.  Example :  Dim. "A" = 10"         Dim. "B" = 42"      Result Dim. "C" = 38-7/8".
    b.  If Dim. "A" or Dim. "B" falls between dimensions listed in the table
         below, allow for difference.
         Example :  Dim. "A"= 7"           Dim. "B" = 36"      Then Dim."C" = 33-1/8".
    c.  If Dim. "A" and Dim. "B" intersect in the shaded area,

 DO NOT INSTALL

 magnet box.

         The degree of door opening will not allow for proper alignment between armature and
         wall magnet.
4. Suggested vertical location is on top rail approximately 5" from top of the door.

5. Check degree of door opening shown in table and coordinate with door closer and

   other door hardware.

6. Total projection of door hardware must not be more than 3-5/8" on the pull side of door.

    If greater, you will need to use additional extensions, sold separately.

7. From corner of wall, measure the appropriate Dim. "C" determined in step 3.
8. Proper electrical wire routing must be done before installing magnet box.
9. The 4" x 2-1/8" x 2" outlet box (not provided with unit) should be installed with

    reinforcement to withstand a minimum 50 lb. pull.

IMPORTANT :

 Check that power voltage equals voltage labeled on back of magnet.

                        Consult " ELECTRICAL DATA" on page 1.

DOOR ARMATURE INSTALLATION:

1.  Place and center the door armature on the surface of the magnet with the two

     holes of the base aligned horizontally.
2.  Gently close the door and adjust the angle of the door armature so the base
     lays flat against the door.

3.  While keeping slight pressure on the door, mark location of door armature

     through the two base holes.
4.  Drill through the door where the two marks are located with 5/16" drill.
     Fasten with the (2)10-32 machine screws & sex bolts provided.

For 2-5/8" Door Projection,
use 1" Extension provided

complimentry

C

A

B

Pivot

Centerline

Magnet Box

Centerline

2-3/4"

4-5/8"

1"

NOTE:

 

1.  All dimensions are provided in inches, unless noted otherwise.

             2.  Additional extensions can be ordered separately to increase the
                  door armature projection : 3/8", 1/2", 3/4", 1", 2", 4" or 6".

1-3/4"

1-5/8"

Dim"C" Deg

Dim "C" Deg

Dim"C" Deg

28

Dim"C" Deg

30

Dim "C" Deg

Dim "C" Deg

32

34

Dim "C" Deg

36

Dim"C" Deg

38

40

Dim"C" Deg

42

Dim "C" Deg

44

46

Dim "C" Deg

48

DIM. "B" (DOOR WIDTH)

2
4
6
8

10
12
14
16
18
20
22
24

Dim.
"A"

Отзывы: