background image

-

Apply thread tap or other approved sealant to the spigot/nipple. Insert the 
arm/dropper and then install the arm/dropper onto the spigot, ensuring it 
is tight, flush with the wall/ceiling, and that the arm outlet is perpendicu-
lar/vertical.

Fit the filter/washer and flow control into the shower head according to the 
diagram.

Note

: The flow control should be inserted with the protruding side into the 

showerhead, taking care not to cause and damage to the flow controller. 
In accordance with AS/NZS3662 CI.6e.

Fit the shower head onto the arm/dropper and ensure it is firmly tightened 
to prevent leaks.

The shower head can be adjusted by swiveling into the desired position.

Note

: These showers may not be suitable for use with gravity fed water 

heaters, low and unequal pressure supply networks, instantaneous water 
heaters, tempering valves and/or thermostatic mixing valves. In accor
dance with AS/NZS3662 CI.6c.

The following pressure range should be complied with:
      ·Minimum working pressure 150Kpa
      ·Maximum working pressure 750Kpa

1.

2.

3.

4.

Installation Guide

ALL ABEY SHOWERS MUST BE INSTALLED IN ACCORDANCE WITH 
AS/NZS3500 SERIES.

ALL ABEY SHOWERS ARE CERTIFIED IN ACCORDANCE WITH 
AS/NZS 3662:2005, LICENCE NUMBER WM-022172.