Key Functions
•
• Press once to turn machine on. You will hear two beeps and the light will
illuminate green (solid or flashing depending on mode).
• Press the power button a second time and you will hear one beepas the machine
shuts down. Note that there is a 1 minute fan delay.
Use this button to turn the dehumidifier on and off.
1.
Power
Key
• Use the up and down arrows to set the desired humidity setpoint on the display
screen.
• The setpoint can be any number between 36%-90%. When the
indoor humidity is
higher than the setpoint, the unit will operate.
• Keep in mind that the displayed humidity levels are approximate( +/-5%)
2.
Arrow Buttons
3.
Continuous Mode
•
To set the unit to run continuously regardless of humidity, simply use the down arrow
key to set the humidity below 36%.
The continuous light will illuminate green and the display will show“CO”
.
•
To switch back to normal humidistat operation, use the arrow keys to move the setpoint above
36%.
•
•
If you need to store or move your dehumidifier, press the “Drain” button to remove water
from the integral pump’s reservoir.
4.
Manual Drain Button
•
If the pump reservoir level gets too high, the water sensor will activate to prevent overflow.
•
When this occurs, the compressor will stop automatically, and the display will show “E4”.
After a 1 minute delay, the fan motor will turn off and the dehumidifier will not operate until the
problem has been resolved.
•
Check to verify that the pump is functioning, then unplug the unit for. two minutes to reset the
error code.
5. Pump Trouble Warning
Indicator Lights
•
The display screen has two functions:
1. Humidity Display Screen
1. When the unit is powered on, it shows the humidity of the space.
2. When setting the desired humidity level, the screen will show the set point. After a brief
delay, it will revert to current humidity of the space.
•
• Always make sure the unit is “off” prior to performing any service, unless otherwise
indicated.
• If the humidity is above the setpoint, the light will be solid green and the machine will
operate.
• If the humidity is below the setpoint, the unit will be in standby mode and the light will
be flashing.
This light indicates that the unit is properly powered on and ready to operate.
2. Power Indicator Light
•
When the light illuminates green, it indicates that the dehumidifier is set to continuous
operation mode.
• When the light illuminates red, it means the unit is in auto defrost mode and clearing
the evaporator coils of any ice buildup.
3
.
Continuous Mode/ Auto Defrost Light
•
When the light illuminates red, it indicates the compressor has been initiated but is
currently warming up.
• Once the light switches to green, it means the compressor is currently in working status.
4
.
Compressor Light
5