TH-308GB UHF SERVICE MANUAL
- 33 -
Receiver section
Measurement Adjustment
Item Condition
Test equipment
Terminal
Parts method
Specification
/
Remark
1
.
Band
pass-filter
1) CH
:
RX center
2)Tra generator output
-40dBm
Connect the spectrum
analyzer to TP2 terminal
Tra generator
Spectrum Analyzer
ANT
R194
TC3
TC4
Adjust the
frequency so
that it becomes
the spectrum
waveform
shown in fig1.
2
.
Audio
Lever
1)CH
:
Rx center
SSG output
:
-80dBm(501
μV)
MOD:1KHz
DEV:±3.0KHz(Wide)
±1.5KHz(Narrow)
Check
0.63Vrms
3
.
Sensitivity
1)CH
:
RX center
CH
:
RX LOW
CH
:
RX HIGH
SSG output
:
-116dBm(0.35
μ
V)
MOD:1KHz
DEV:±3.0KHz(wide)
±1.5KHz(narrow)
Check
SINAD
:
12dB
or higher
1)CH
:
RX center
MONI
:
on
2)Level 9
SSG output
:
-117dBm
Level 9
Adjust to close
the squelch
The squelch
must be closed
4. Squelch
Level ( PC
mode)
3)Level 3
SSG output
:
-125dBm(0.126
μV)
SSG
Oscilloscope
AF.V.M
Distortion meter
Antenna
Speaker
PC
key
Level 3
Adjust to close
the squelch
The squelch
must be closed
Содержание TH-308GB UHF
Страница 29: ...TH 308GB UHF SERVICE MANUAL 28 Exploded View ...
Страница 30: ...TH 308GB UHF SERVICE MANUAL 29 Packing View ...
Страница 36: ...TH 308GB UHF SERVICE MANUAL 35 BPF Wave Figure 1 ...
Страница 40: ...TH 308GB UHF SERVICE MANUAL 39 TH308GB Parts View Side A ...
Страница 41: ...TH 308GB UHF SERVICE MANUAL 40 TH308GB Parts View Side B ...
Страница 42: ...TH 308GB UHF SERVICE MANUAL 41 TH308GB PC Board View Side A ...
Страница 43: ...TH 308GB UHF SERVICE MANUAL 42 TH308GB PC Board View Side B ...