4. Operations
Control Panel Menu Item Descriptions
Control Panel Menu Item Descriptions
This section of this chapter describes in detail the menu parameter items in each of the
three main menus: Main Menu, Options Menu and User Memory Menu.
Main Menu Parameters
The items in the Main Menu are used to program Primary System Configuration
parameters of AirCleaner. Changes made to any of the parameter values in the Main
Menu are immediately enacted and saved to the operating memory inside AirCleaner.
The following descriptions appear in the order in which they appear in the menu tree:
This parameter has two possible settings:
•
= One
A single operator (screener) will control AirCleaner.
The entire “total program delay” value is applied to
this single user. This “Screener 1” operator monitors
the incoming audio/video feeding into AirCleaner to
screen for violations; the
PGM OUT
provides the
delayed “on-air” audio/video from AirCleaner.
•
= Two
Two operators (screeners) will control AirCleaner.
The “total program delay” value is split between the
two operators. The “Screener 1” operator monitors the
incoming audio/video feeding into AirCleaner, while
the “Screener 2” operator monitors the audio/video
output from the
TAP OUT
of AirCleaner to screen for
violations; the
PGM OUT
provides the delayed “on-
air” audio/video from AirCleaner.
The
Screeners
parameter determines how many operators will be controlling
AirCleaner (either one or two operators, or “Screeners”). When set to “
Two
”, the
“
Screener 2 Delay
” parameter determines how much of the total program
delay is assigned to Screener 2.
WARNING
DO NOT ADJUST PARAMETERS WHILE LIVE “ON-AIR”
Changes made to all parameters in the Main Menu will take effect
as the parameter is being changed. Depending on the parameter
being changed, this could disrupt the LIVE audio/video outputs!
Changes made to all parameters in the Options Menu require:
•
TURN the
SELECT
knob to reveal the “Save Changes?” item.
•
PUSH the
SET
knob to “OK” the save operation.
Saving any change to any parameter in the Options Menu could
severely disrupt the audio/video outputs from AirCleaner; these
changes should NEVER be saved while using AirCleaner live on
the air!
Screeners
= One
Содержание AirCleaner
Страница 2: ...ii AirCleaner User Guide ...
Страница 10: ...x AirCleaner User Guide Table of Contents ...
Страница 54: ...44 AirCleaner User Guide 3 Updating Software Firmware Updating Software Firmware ...
Страница 100: ...90 AirCleaner User Guide 4 Operations Control Panel Menu Item Descriptions ...
Страница 106: ...96 AirCleaner User Guide Index ...