Step 6 – Attach Drain Line to Fleck Meter
1. Wrap threaded connection point with 3-4
wraps of Te lon tape. Install provided plastic
barbed itting.
2. Install drain line (not included) to barbed
itting (found on Fleck valve) with a stainless
hose clamp (not included). Drain line should
extend to a main drain to dispose of waste
water.
Attach Tank Lines
Step 7 – Connect Brine Line to Fleck Meter
1. Prep brine line prior to install using brass nut,
plastic Ferrule & brass tube insert.
2. Connect provided brass nut to the Fleck valve. Be
careful not to overtighten. Overtightening will cause
damage.
Step 8 – Connect Brine Well to Tank Side Wall
1. Locate predrilled hole in brine tank. Fas-
ten brine well to side wall of brine tank using
the white over low elbow & plastic nut.
* This is preinstalled on Space Saver version.