Страница 1: ...ABCwaters Fleck 5600SXT Water Softener Install Guide Written by 602abcWATER ...

Страница 2: ...metered valve 1 1 Threaded Yoke 1 Bypass 1 Blue 602abcWATER bag ABCwaters brand listings only 1 Small tube of silicone lubricant 1 Sanitizer packet 1 Water hardness test strip Not included but required Salt Te lon Tape ittings to connect softener to your plumbing ID drain line Please be sure to visit our website for installation resources to assist you during your install Phone 602 222 9283 Monday...

Страница 3: ...asket to the bottom of the Fleck 5600sxt valve Insert large end of basket into groove and turn clockwise into locking position 3 Apply a thin layer of the provided silicon to large O ring located outside of threads 4 Connect the Fleck valve to the mineral tank Be sure to carefully line up the meter s top basket to the mineral tank s distributor tube The mineral tank s distributor tube should it in...

Страница 4: ...ause the connection is O ring sealed it s important not to overtighten the screw Overtightening will cause damage to the plastic assembly Meter Valve Assembly Step 5 Connect Yoke to Bypass 1 Apply silicone lube to the 2 o rings on the male connection on valve Again we also rec ommend applying silicone to the inside of the female end of the yoke prior to connecting 2 Position both metal clips to cl...

Страница 5: ... to dispose of waste water Attach Tank Lines Step 7 Connect Brine Line to Fleck Meter 1 Prep brine line prior to install using brass nut plastic Ferrule brass tube insert 2 Connect provided brass nut to the Fleck valve Be careful not to overtighten Overtightening will cause damage Step 8 Connect Brine Well to Tank Side Wall 1 Locate predrilled hole in brine tank Fas ten brine well to side wall of ...

Страница 6: ...ine to the Fleck meter through the port with arrow pointing toward the meter 2 Connect the remaining port with arrow pointing away from meter to the home s incoming water line Step 11 Connect Meter to Power Source 1 Plug in the Fleck 5600sxt digital meter to a power receptacle Your power source should be less than 5 feet in distance from the Fleck meter 2 Turn bypass to in service and let the tank...

Страница 7: ...Day Override This may take 5 seconds before change Step 3 Select of days for DO We suggest 14 days Press Cycle button icon of arrows in diamond pattern after days are set Step 4 Set Regeneration Time RT We suggest setting to 2 00am This is the time that the system will regenerate Press Cycle button after setting time Step 5 Set Hardness H Based on hardness test number Press Cycle button after set ...

Страница 8: ...able Monday thru Friday between the hours of 7am to 4pm AZ time 23910 N 19th Ave Ste 8 Phoenix Arizona 85085 Web www 602abcwater com Phone 602 222 9283 Email support 602abcwater com Text or Facetime 602 321 0145 We want to thank you for choosing our business for your water treat ment needs We would like to show our gratitude by offering a limited time discount on your next purchase Please call us ...