6
www.abcoolairhvac.com
SS-ABGMEC80/ABGCEC80
SS-ABGMEC80/ABGCEC80
www.abcoolairhvac.com
7
GCEC80 Dimensions
A
B
High-Voltage
Electrical
Low-Voltage
Electrical
Gas Inlet
11
⅜”
18
⅜”
19
⅝”
33
⅜”
28
”
Minimum Clearances to Combustible Materials
Sides
Rear
Front ¹
Vent ²
Top
SW
B
1
0
3
6
1
1
Approved for line contact in the horizontal position.
¹ 24” clearance for serviceability recommended.
² Single Wall Vent (SW) to be used only as a connector. Refer to the venting tables outlined in the
Installation Manual for additional venting requirements.
Model
Dimensions
W
D
H
GCEC800403A*
14”
28”
33⅜”
GCEC800603A*
14”
28”
33⅜”
GCEC800603B*
17½”
28”
33⅜”
GCEC800804B*
17½”
28”
33⅜”
GCEC800805C*
21”
28”
33⅜”
GCEC801005C*
21”
28”
33⅜”
Model
Description
LPM-08
LP Conversion Kit (Springs & Orifice)
AM11-1425-FA
Deep Pleated Media Air Cleaner
AM11-1625-FB
Deep Pleated Media Air Cleaner
AM11-2025-FC
Deep Pleated Media Air Cleaner
AM11-2525-FD
Deep Pleated Media Air Cleaner
Accessories
Model
Plenum Opening Dimensions
A
B
GCEC800403A*
14"
12½”
GCEC800603A*
14"
12½”
GCEC800603B*
17½”
16"
GCEC800804B*
17½”
16"
GCEC800805C*
21"
19½”
GCEC801005C*
21"
19½”