background image

Do not instal within 10 feet of a pool, spa or fountain

CAUTION:

Fixture(s) must be installed in accordance with all local codes and ordinances.

INSTALLATION INSTRUCTION

To  ensure  optimal  performance  and  safety,  it  is
important  to  use  our  fixtures  ONLY  with  a  low
voltage  landscape  transformer.  This  transformer
reduces  the  voltage  from  120V  to  12V,  making  it
safe and suitable for outdoor use.

When installing the fixture(s), please follow these
instructions carefully:

1.Before installation, please ensure that the power
is turned off for your safety.            

2.Observe  the  upper  portion  of  the  fixture.    To
detach  the  face  plate,  simply  loosen  the  screws
and  proceed  to  remove  the  top  cover  and  glass
from the housing.

3.Locate  the  socket  where  the  lamp  will  be
inserted.  Align  the  lamp's  base  or  pins  with  the
corresponding slot in the socket. Gently push the
lamp into the socket, ensuring a secure and snug
fit.

4.Carefully  position  the  top  part  of  the  fixture
above the lower part. Carefully tighten the screws
in a clockwise direction until you feel the top part
properly  engaging  with  the  lower  part  until  it  is
securely fastened. 

5.  Select a suitable spot where you intend to dig
the  hole,  considering  factors  such  as  purpose,
accessibility,  and  any  relevant  guidelines  or
regulations.  Gradually  dig  deeper,  removing  the
loosened  soil.  Calculate  the  approximate  volume
of  pea  gravel  or  sand  required  to  fill  the  cleared
space, taking into account the 3-inch clearance on
all sides. 

Inspect  the  hole  and  surrounding  area  to  ensure
that  the  depth,  width,  and  clearance  meet  the
specified requirements.

www.ABBALightingUSA.com

6. Using a suitable main cable connector for direct
burial,  attach  the  fixture(s)  wires.  We  recommend
using 

WN12

 waterproof wire nuts (sold separately)

for  optimal  connectivity.  To  establish  a
dependable  and  enduring  electrical  connection
between fixture wires and the main line in outdoor
or  underground  installations,  it  is  essential  to
select  a  suitable  main  cable  connector  designed
for direct burial. This connector should be chosen
based  on  its  ability  to  withstand  environmental
conditions,  resist  moisture  and  corrosion,  and
provide robust insulation. By adhering to industry
standards  and  best  practices,  including  proper
wire  stripping  and  secure  fastening  techniques,  a
reliable  connection  can  be  established,  ensuring
optimal performance, safety, and longevity of the
system.

7.Strip 

the 

insulation: 

Carefully 

strip

approximately 3/4 inch (1.9 cm) of insulation from
the  ends  of  the  two  wires  you  wish  to  connect.
Ensure that the bare metal ends are clean and free
from any frayed strands.

8.  Align  the  wires:  Hold  the  stripped  ends  of  the
two  wires  together,  aligning  them  neatly  and
ensuring that no stray strands are crossing over.

9. Insert the aligned ends of the wires into the wire
nut, ensuring that they go all the way in. The bare
ends  should  be  completely  covered  by  the  wire
nut.  Twist  the  wire  nut:  Firmly  twist  the  wire  nut
clockwise  onto  the  wires,  ensuring  a  secure
connection. Continue twisting until the wire nut is
tight  and  snug.  For  added  safety,  it  is
recommended to apply electrical tape around the
wire nuts and wires as an extra layer of protection.

10.Test the connection: Gently tug on each wire to
ensure they are securely held by the wire nut. 

Содержание UNB12

Страница 1: ...UNB12 www ABBALightingUSA com INSTALLATION GUIDE ...

Страница 2: ...ctions before assembly installation and use By doing so you ll not only guarantee correct function and safety but also optimize the full potential of this exceptional product Thank you for choosing us as your trusted provider of top notch products we truly appreciate your business WARRANTY We stand behind the quality of our product and offer a 2 year warranty from the date of purchase Please note ...

Страница 3: ...dth and clearance meet the specified requirements www ABBALightingUSA com 6 Using a suitable main cable connector for direct burial attach the fixture s wires We recommend using WN12 waterproof wire nuts sold separately for optimal connectivity To establish a dependable and enduring electrical connection between fixture wires and the main line in outdoor or underground installations it is essentia...

Страница 4: ...lowing it to fill the space between the fixture and the hole c Use a shovel or similar tool to gently pack the pea gravel or sand ensuring it settles evenly and provides stable support Step 4 Verify the completed installation a Inspect the fixture to confirm that it is securely positioned in the hole b Check that the pea gravel or sand fills the extra space adequately providing proper drainage aro...

Страница 5: ...www ABBALightingUSA com 3 Gravel 3 Gravel Both sides Below Concrete Main line WN12 Sold separately 3 Gravel 3 Gravel Both sides Below Soil Main line WN12 Sold separately ...

Отзывы: