2104349 rev. AD
Page 2
–5
-
Stainless steel tubing
2.2.3.3
Step-by-step instructions
To install the G4 EX, it is recommended that two people
perform the installation. One to hold the unit in position and
the other to install and tighten the mounting brackets.
The method of installation must be consistent with the user’s
company policy.
1)
Attach the pole mount bracket to the top of the 2” pipe with the U-bolts. Use
the provided hex nuts, flat washers and spring lock washers to tighten the
pole mount bracket to the 2” pipe.
Position the mounting bracket high enough on the pipe to
allow slope from the externally mounted manifold to the tap
valves.
2) Position the provided back clamp on the pole mount bracket, and align the
mounting holes between the two pieces.
3) Upon alignment, take the G4 EX and its attached transducer and set it
within the recessed groove on the back clamp.
4) Once the G4 EX and its transducer have been properly positioned, attach
the device to the brackets using the provided U-bolt. Use the hex nuts, flat
washers and spring lock washers to tighten the device to the mounting
brackets (see Figure 2
Figure 2
–3 Type C installation configuration
Pole Mount Bracket
Back Clamp