In the G4 EX computer, the status and alarm indicators are user programmable.
Table 1
–3 identifies the default annunciator locations. Please consult the PCCU32
Help Files for additional instructions on programming the annunciators.
Whenever an alarm is indicated, the G4 EX records it in the appropriate log period
flow record. These are automatically retrieved when data is collected. Visual
alarms and status codes are described in Table 1-4.
Figure 1
–2 Liquid Crystal Display (LCD) and indicators
Table 1
–3 Default annunciator locations
Annunciator
Application
A1
Measurement Tube 1
A2
CIM 0
A3
Valve Control
A4
COM2
A5
Plunger
A6
Local-COM0
A7
System
A8
TF Remote
– COM1
Table 1
–4 G4 EX status and alarm description
Indicator
Description
System
LL
Low Lithium Battery Alarm: When LL (low lithium) is displayed, lithium battery voltage is not
sufficient to maintain SRAM data. A new lithium battery measures approximately 3.6 VDC.
Display Application
1
A number represents the Display Group number currently being displayed.
↑
The displayed item’s value is above the Data High Limit value specified on the display Item
Setup screen.
↓
The displayed item’s value is below the Data Low Limit value specified on the display Item
Setup screen.