Operation Manual / 4 Product description / A100-L
8 Disassembly and assembly / 8.14 Fitting the gas inlet casing (
≤
A175-
L)
© Copyright 2020 ABB. All rights reserved.
HZTL4034_EN
Rev.P
January 2020
8.14
Fitting the gas inlet casing (
≤
A175-L)
8.14.1
Variant with screws
Fig. 49: Fitting the gas inlet casing (A175-L and smaller) – screwed variant
Product
Size
Tightening torque [Nm]
A165-L
M16
30
1)
/ 140
A170-L
M18
40
1)
/ 200
A175-L
M22
50
1)
/ 380
Table 34: Tightening torque (61009)
1) Pre-tightening torque of the screws
1. Fit two guide studs (90317) in the upper area on the gas outlet casing (61001).
2. Loop around the gas inlet casing (51001) with the lifting gear and secure it to the crane.
3. Push gas inlet casing over the guide studs up to the gas outlet casing.
4. Coat two opposite screws (61009) with high-temperature grease and screw in.
Page