background image

2TMD041800D0002

26.07.2019

Product manual

ABB

-

Welcome IP

H8236.

-

. IPTouch 7"

H8236.

-

.

-

02 IPTouch 7"

Содержание Welcome IP IPTouch 7" Series

Страница 1: ...2TMD041800D0002 26 07 2019 Product manual ABB Welcome IP H8236 IPTouch 7 H8236 02 IPTouch 7 ...

Страница 2: ...installation 23 7 7 Desktop installation 24 7 8 Dismantling 25 7 9 Replacing the end strip 25 8 Commissioning 26 8 1 Initial setup 26 8 2 System settings 30 8 2 1 Enter system setting 30 8 2 2 Sound 31 8 2 3 Language 32 8 2 4 Network settings 33 8 2 5 Automatic snapshot 36 8 2 6 Address of default lock 37 8 2 7 Program button setting 39 8 2 8 Card management 41 8 2 9 Display 45 8 2 10 Date and tim...

Страница 3: ...e 112 9 4 1 Surveillance from outdoor station 112 9 4 2 Surveillance from IP camera 114 9 5 Call guard unit 115 9 6 History 117 9 7 Voice message 120 9 8 Absence message 122 9 9 Automatic unlock 124 9 10 Standby unlock 126 9 11 Mute 128 9 12 Text message 129 9 13 Mediaplayer 132 9 13 1 Multi media 132 9 13 2 Photo album 133 9 14 Call the lift 134 9 15 Alarm 136 9 15 1 Basic zone settings 137 9 15 ...

Страница 4: ...Table of contents Product manual 2TMD041800D0002 4 ...

Страница 5: ...ep this manual in a safe place If you pass the device on also pass on this manual along with it ABB accepts no liability for any failure to observe the instructions in this manual 2 Safety Warning Electric voltage Dangerous currents flow through the body when coming into direct or indirect contact with live components This can result in electric shock burns or even death Disconnect the mains power...

Страница 6: ...n loop H82365 H82365 02 IP touch 7 LAN LAN with induction loop H82366 H82366 02 IP touch 7 LAN with induction loop WIFI installation Note If the device support WIFI function please make sure the device has good WIFI signal reception before installation The distance between the router and monitors and the construction materials used in the walls are factors that can affect signal quality The WIFI s...

Страница 7: ...de If H82366 is set to independent mode no other devices can be supported The indoor station can be managed by using management software Switch Master mode Master mode Independent mode Subsidiary mode Subsidiary mode Subsidiary mode Optional Optional Router Home Community LAN1 LAN1 LAN1 LAN1 LAN2 LAN1 IP actuator IP actuator IP pushbutton OS IPS IPR SysAP KNX Free home H82365 H82364 H82366 H82364 ...

Страница 8: ...tting Basic zone setting Set alarm timer Arm or disarm the indoor station H82365 only On the System settings Change password screen click Change user password to change the user password Password rule This password must not include continuously increasing or decreasing numbers e g 123456 654321 Three consecutive identical numbers are similarly not permitted e g 123444 666888 ...

Страница 9: ...ystem default is 345678 On the Engineering settings Advance zone settings screen click Change program password to change the program password Password rule This password must not include continuously increasing or decreasing numbers e g 123456 654321 Three consecutive identical numbers are similarly not permitted e g 123444 666888 ...

Страница 10: ...assword when accessing the engineering settings for the first time This engineering password must not include continuously increasing or decreasing numbers e g 123456 654321 Three consecutive identical numbers are similarly not permitted e g 123444 666888 Forgotten engineering password Please contact the technical support engineers if you forget the engineering password Wrong password If the wrong...

Страница 11: ...e password On the System settings Change password screen click Change unlock password and enter the new password twice to change the password 3 8 digits Password rule This password must not include continuously increasing or decreasing numbers e g 123456 654321 Three consecutive identical numbers are similarly not permitted e g 123444 666888 ...

Страница 12: ... Home screen displays a at the bottom The system default home screen is Home automation screen The Home screen can be set on the Engineering setting screen Please see the Device settings chapter for more details Extra screen The Extra screen displays at the bottom ...

Страница 13: ...e recording or copying images onto the SD card otherwise this SD card may fail to preform when recording or playing images ABB is no responsible for the performance of an SDHC card IP Cam Note The indoor station supports IP Cam with onvif protocol Profile S Ringtone Note The ringtone supports mp3 and wav format with a maximum size of 32 M Audio and video file Note The audio file supports mp3 and w...

Страница 14: ...y 4 1 ABB devices All packaging materials and devices from ABB bear the markings and test seals for proper disposal Always dispose of the packing materials and electric devices and their components via an authorized collection facility or disposal company ABB products meet the legal requirements in particular the laws governing electronic and electrical devices and the REACH ordinance EU Directive...

Страница 15: ...Product description Product manual 2TMD041800D0002 15 5 Product description 5 1 Control elements No Function 1 Touch screen ...

Страница 16: ...JACK input 3 Doorbell connector 4 LAN1 PoE 5 Micro USB Upgrade connector 6 3 Extension module connector 7 Microphone 8 Dismantling switch 9 Micro SD card connector 10 Speaker 11 2 LAN2 12 2 Alarm connector 13 2 RS485 connector 12 V output emergency port SOS GAS fire 14 2 Relay output 2 for H82365 3 for H82366 5 7 8 9 10 6 11 12 13 14 1 2 3 4 ...

Страница 17: ...dard IEEE802 3 af 2 Alarm power output 12 V DC 200 mA 2 Relay output 30 V DC 1 A 1 Wireless transmission band 802 11b g n 2412 2462MHz for United States 2412 2472MHz for European countries 802 11a n 5150 5250MHz 5250 5350MHz 5470 5725MHz 5725 5850MHz for United States 1 Wireless transmission rate Max 100 Mbps 1 Wireless transmission power Max 20 dBm 12 Mbps OFDM 2 4 G Max 20 dBm 12 Mbps OFDM 5 8 G...

Страница 18: ...edge and experience Incorrect installation endangers your life and that of the user of the electrical system Incorrect installation can cause serious damage to property e g due to fire The minimum necessary expert knowledge and requirements for the installation are as follows Apply the five safety rules DIN VDE 0105 EN 50110 1 Disconnect 2 Secure against being re connected 3 Ensure there is no vol...

Страница 19: ...Mounting Installation Product manual 2TMD041800D0002 19 7 2 Product dimensions 7 3 Installation height 1 50 m 4 9 feet ...

Страница 20: ... installation This installation method is only suitable for H82361 H32364 and H82366 and is not suitable for H82365 Surface mounted box 170 8 mm 1 31 4 mm Global 60 mm VDE BS CN 120 7 mm 120 7 mm NEMA NEMA Italy Swiss 83 3 mm 8 3 3 mm 7 9 2 m m 83 3 mm 83 3 mm 89 mm 89 mm NEMA ...

Страница 21: ...Mounting Installation Product manual 2TMD041800D0002 21 Installation 1 4 5 3 2 ...

Страница 22: ...Mounting Installation Product manual 2TMD041800D0002 22 7 5 Flush mounted installation Pre installation box Installation 4 5 1 2 3 6 7 8 9 10 11 ...

Страница 23: ...Mounting Installation Product manual 2TMD041800D0002 23 7 6 Cavity wall installation 1 2 3 4 5 7 6 8 9 ...

Страница 24: ...Mounting Installation Product manual 2TMD041800D0002 24 7 7 Desktop installation This instalation is only fit for H82361 H32364 and H82366 not fit for H82365 2 3 4 5 1 ...

Страница 25: ...Mounting Installation Product manual 2TMD041800D0002 25 7 8 Dismantling 7 9 Replacing the end strip 1 2 1 2 3 4 ...

Страница 26: ...ioning 8 1 Initial setup This indoor station enters initial setup automatically when powered on the first time or Clear all data is carried out on the Engineering settings screen Please see the Clear all data chapter for more details 1 Select system language ...

Страница 27: ...Commissioning Product manual 2TMD041800D0002 27 2 Accept licensing terms ...

Страница 28: ...Commissioning Product manual 2TMD041800D0002 28 3 Select country 4 Set date and time ...

Страница 29: ...Commissioning Product manual 2TMD041800D0002 29 5 Set WIFI H82364 only Please see the Network settings chapter for more details ...

Страница 30: ...Commissioning Product manual 2TMD041800D0002 30 8 2 System settings 8 2 1 Enter system setting On the extra screen click System to access the corresponding screen ...

Страница 31: ...2 Ringtone setting Click the drop down list to select the ringtones for outdoor station indoor stations guard unit and doorbell built in 4 ringtones 3 Customized ringtone A maximum of 3 customised ringtones can be added from an SD card 4 Volume settings Adjust the volume of the ringtone 5 Repeated tone setting ON repeated ringtone within 30 s OFF rings only once ...

Страница 32: ...Commissioning Product manual 2TMD041800D0002 32 8 2 3 Language On the System settings screen click Language and select the system language ...

Страница 33: ...oadcast function is used on the router On the System settings screen click Network settings WIFI settings The indoor station will obtain an SSID list automatically Select a WIFI name from the SSID list and enter the password to connect to that WIFI network Go back to the Network settings screen and the WIFI name will appear if successful ...

Страница 34: ...the designated WIFI name from the SSID list click Ignore or Disconnect to disconnect the WIFI Ignore password needed to reconnect this WIFI Disconnect no password needed to reconnect this WIFI Go back to the Network settings screen the WIFI name will disappear if successful ...

Страница 35: ... Product manual 2TMD041800D0002 35 IP address setting The indoor station uses DHCP to obtain an IP address from the router by default It is also possible to set the IP address by unticking the checkbox example below ...

Страница 36: ...41800D0002 36 8 2 5 Automatic snapshot On the System settings screen click Door Entry System and tick the Automatic snapshots checkbox to enable the function The indoor station will take 3 snapshots automatically during an incoming call ...

Страница 37: ... 2TMD041800D0002 37 8 2 6 Address of default lock On the System settings screen click Door Entry System Address of default unlock and select the lock type e g door lock followed by the device e g OS 02 Click OK to save the setting ...

Страница 38: ...ctivated on the Door entry screen Click the first icon to release the default lock of the outdoor station Click the second icon to release the auxiliary lock of the outdoor station by default The other function can also be set Please see the Program button settings chapter for more details ...

Страница 39: ...ings screen click Door Entry System Program button setting The program button is set to Open auxiliary lock by default The Program button function will be disabled if Invalid is set The program button can be set to Turn on the light and you need to select IP actuator type and enter the device no ...

Страница 40: ...Commissioning Product manual 2TMD041800D0002 40 On the Door entry screen a light icon will be displayed Click this icon to turn on IP actuator light ...

Страница 41: ...r IP pushbutton outdoor station Note It is recommended that IC cards are created and maintained using local outdoor stations or management software only On the System settings screen click Door Entry System Card management and enter the user password the system default is 123456 to access the corresponding screen ...

Страница 42: ... will flash orange as a prompt to swipe an IC card 2 Exit registration mode Press the first button on the outdoor station to exit registration mode If an IC card has been registered the outdoor station will exit registration mode automatically if no operations are carried out within 15 s If no IC card has been registered the outdoor station will exit registration mode automatically if no operation...

Страница 43: ...r station will flash orange as a prompt to swipe an IC card 2 Exiting delete mode Press the first button on the outdoor station to exit delete mode If an IC card has been deleted the outdoor station will exit delete mode automatically if no operations are carried out within 15 s If no IC card has been deleted the outdoor station will exit delete mode automatically if no operations are carried out ...

Страница 44: ...MD041800D0002 44 Card clear On the Card management screen click Card clear select the device and click Card clear Card sync On the Card management screen click Card sync select a source device and a target device then click Card sync ...

Страница 45: ...sponding screen No Function 1 Clean screen Please see the Clean screen chapter for more details 2 Brightness 3 Screensaver Digital clock displays the current time at a random position on the screen Built in picture displays 3 built in pictures External picture displays pictures stored on the SD card 4 Auto full screen default ...

Страница 46: ...nd time to access the corresponding screen No Function 1 Sync time type Tick the checkbox to sync date and time from the management software or from NTP automatically 2 Time and date setting 3 Set time zone If you don t sync date and time from management software or from NTP You need to set time zone before use ...

Страница 47: ... Home monitor The indoor station and the camera must be on the same network Note Video streaming between the indoor station and the 3rd party camera is unencrypted On the System settings screen click Monitor settings Home monitor then click to access the corresponding screen ...

Страница 48: ...ioning Product manual 2TMD041800D0002 48 Click to search the IP Cams and create a camera list automatically Select a camera from the camera list and click Enter the name user account and password then click OK ...

Страница 49: ...ssioning Product manual 2TMD041800D0002 49 On the Home monitor screen tick Enable to enable the function With this setting the register IP Cam can be selected from the drop down list on the Door entry screen ...

Страница 50: ...duct manual 2TMD041800D0002 50 2 Community monitor On the System settings screen click Monitor settings Community monitor to access the corresponding screen Click to download the camera list from the management software ...

Страница 51: ...ettings 1 Registering an account on the MyBuildings portal Access the link https mybuildings abb com and click Register Fill in the form as required to register an account Then activate the user account when you receive the email sent from the MyBuilding portal ...

Страница 52: ...Commissioning Product manual 2TMD041800D0002 52 2 Logging into the MyBuildings portal on the indoor station ...

Страница 53: ... the APP Store via the keyword ABB Welcome Then install the relevant APP on mobile or tablet Note The following snapshots used in this document were taken on the IOS system On the mobile tablet click to open the APP Note It is recommended to accept the permissions of the microphone camera and notification for further use ...

Страница 54: ...manual 2TMD041800D0002 54 If you do not grant the permissions you will be able to add them later on For example click to access the settings screen on the mobile swipe the screen down and then click to accept the permissions ...

Страница 55: ...mobile phone tablet click to open the app enter the user name password and alias tick the checkboxes to accept all the terms and conditions then click Log in Note If an incorrect password is entered more than 3 times no further attempts are permitted within certain period of time ...

Страница 56: ...airing the devices On the APP Home screen tap followed by Pair devices IP gateway Then tap to call up the device list and select the alias click OK to send a pairing request to the indoor station Please write down the token ID e g 1849C4BC in this case ...

Страница 57: ...Commissioning Product manual 2TMD041800D0002 57 On the System settings APP settings screen of the indoor station click Unpaired select the relevant functions in the pop up window and click Pair ...

Страница 58: ...Commissioning Product manual 2TMD041800D0002 58 Enter the token ID and click OK The indoor station will display Paired if successful ...

Страница 59: ...Commissioning Product manual 2TMD041800D0002 59 6 Portal Sync If you have purchased a remote service you can click Portal sync on the APP settings screen to enable the remote service immediately ...

Страница 60: ...2 13 Contacts On the System settings screen click Contacts to access the corresponding screen Click Contacts to manage the contacts Click Add manually enter a name and room number then click OK to save the setting A maximum of 64 contacts can be added ...

Страница 61: ...uct manual 2TMD041800D0002 61 8 2 14 Reset user settings On the System settings Reset settings screen Click Reset user settings enter the user password the system default is 123456 and click OK to reset the user settings ...

Страница 62: ...Commissioning Product manual 2TMD041800D0002 62 8 2 15 Version information On the System settings screen click About to view the version information ...

Страница 63: ...Commissioning Product manual 2TMD041800D0002 63 8 2 16 Device address On the System settings screen click About to view the address information ...

Страница 64: ...ommissioning Product manual 2TMD041800D0002 64 8 2 17 Firmware update It is possible to obtain the latest version on the website via scanning the QR code Click Documentation Software to download the file ...

Страница 65: ...g Product manual 2TMD041800D0002 65 Note This function is only available when an SD card is inserted On the System settings About screen click Firmware update click the file and then click OK to update the firmware ...

Страница 66: ...settings 8 3 1 Enter engineering setting the On the System settings screen click Engineering settings enter the engineering password to access the settings screen Note The settings screen will turn back to the home screen if no operations are carried out within 60 s ...

Страница 67: ...all mode Select call mode between Physical address default and Logical address 2 Mode select Please see the Intended use Application chapter for more details 3 Home network port If Master mode LAN1 LAN2 for H82365 Wifi by default for H82364 If Subsidiary mode LAN1 LAN2 for H82365 LAN Wifi for H82364 ...

Страница 68: ...reen setting Home automation default DES page 2 Additional function on DES screen Enable disable the function displayed on the door entry screen e g call lift call guard unit 3 Additional function on Extra screen Enable disable the function displayed on the extra screen e g alarm auto unlock ...

Страница 69: ...missioning Product manual 2TMD041800D0002 69 Screen saver settings Click to change the screensaver picture from the SD card Default guard unit Click Address of default guard unit and enter the address 1 32 ...

Страница 70: ...onding screen Click Export configuration file to output a configuration file to the SD card Click Export System Log to output a system log to the SD card System log includes the events such as updating firmware changing configuration entering wrong password changing password etc Click Import configuration file to import the configuration file stored on the SD card ...

Страница 71: ...Remote setting function is only available on the indoor station which is set as Master mode or Independent mode If the Remote setting is enabled default this device can be set by the management software If the Remote setting is disabled this device can only be set by the local management software ...

Страница 72: ...t manual 2TMD041800D0002 72 Clear all data This function is only available within 120 s after the indoor station is powered on All data including user settings and engineering settings will be reset to the factory defaults ...

Страница 73: ...ng mode Power on the outdoor station wait until all 3 LED indicators go out Press the first button on the outdoor station and hold for 10 s until all 3 LED indicators flash Tip The outdoor station will exit engineering mode after 5 minutes Indoor station goes to the settings page On the Engineering settings screen click Outdoor station settings to access the corresponding screen ...

Страница 74: ...ct manual 2TMD041800D0002 74 Device settings Go to the Outdoor station settings screen 1 Device type GS gate station Device no range is 1 32 2 Device type OS outdoor station Block no range is 1 999 device no range is 1 64 ...

Страница 75: ...ioning Product manual 2TMD041800D0002 75 3 Device type 2nd OS 2nd confirmed outdoor station 1 Location Internal The 2nd OS is connected to the router in the apartment see diagram below Device no range is 1 32 ...

Страница 76: ... The 2nd OS is connected to the switch outside the apartment see diagram below Block no range is 1 999 the Room no range is 01 63 01 32 e g 0101 and the device no range is 1 2 Note The external and internal types cannot be used in mixed scenarios in the same apartment ...

Страница 77: ...en No Function 1 Unlock type when swiping Set the lock to be released when swiping Default lock default Subsidiary lock 2 Lock type Set the lock type for the default lock and subsidiary lock Lock GND NO NC COM IP actuator 3 Time of unlock Set the time for unlock Power lock Lock GND Signal lock NO NC COM ...

Страница 78: ...f this function is enable the outdoor station will send an alarm to the management software if the door is open longer than 120 s A sensor should first be connected to the outdoor station 2 Tamper proof alarm If this function is enabled the outdoor station will send an alarm to the management software if the outdoor station is removed from the wall ...

Страница 79: ...outdoor station Click or to adjust the ringtone volume and the voice volume on the outdoor station 2 Button tone Tick the checkbox to enable button tones on the outdoor station 3 Voice prompt Tick the checkbox to enable voice prompts on the outdoor station Choose the language for the voice prompts from the drop down list ...

Страница 80: ... able to use this function The gate station and the 2nd confirmed outdoor station are not able to use this function On the Outdoor station settings page tick the checkbox to enable the function Anti flicker setting On the Outdoor station settings screen select the refresh rate from the drop down list ...

Страница 81: ... this function On the Outdoor station settings screen tick the checkbox to enable the function If this function is enabled each incoming call from this outdoor station will be transferred to the guard unit Wiegand output on the outdoor station On the Outdoor station settings screen tick the checkbox to enable the function Set the Wiegand output from the drop down list 26 bits default or 34 bits ...

Страница 82: ...Commissioning Product manual 2TMD041800D0002 82 ...

Страница 83: ...n of pushbutton On the Outdoor station settings screen click Pushbutton address setting to access the settings of the pushbuttons Columns of button is only available when detecting bar pushbutton module on the outdoor station It can be set to 1 column or 2 columns ...

Страница 84: ...2 84 Time sync setting On the Outdoor station settings screen If Sync time with management is selected the outdoor station will sync the time from the management software If Close time sync is selected the time and date needs to be set manually ...

Страница 85: ...ommissioning Product manual 2TMD041800D0002 85 Security mode and compatible mode setting On the Outdoor station settings screen the outdoor station is set to Security mode by default Compatible mode off ...

Страница 86: ...Firmware update Note The outdoor station must exit engineering mode before the firmware is upgraded On the Outdoor station settings screen click Firmware update select the outdoor station and the file from SD card then click OK to update the firmware ...

Страница 87: ...Commissioning Product manual 2TMD041800D0002 87 Version of outdoor station On the Outdoor station settings screen view the version information ...

Страница 88: ...et button of the IP actuator when it is powered on the LED flashing means that the IP actuator has entered engineering mode On the Engineering setting screen on the indoor station click IP actuator settings to access the corresponding screen Tip The IP actuator will exit engineering mode if no operation are carried out for 5 minutes ...

Страница 89: ...ct manual 2TMD041800D0002 89 Device settings On the IP actuator settings screen 1 Device type Network IP Actuator Device no range is 1 32 2 Device type Building IP actuator Block no range is 1 999 device no range is 1 32 ...

Страница 90: ...ng Product manual 2TMD041800D0002 90 3 Device type Private IP Actuator Location of IP actuator Internal Device no range is 1 32 see diagram below Switch Router Device ID 1 32 Master Home network Community network ...

Страница 91: ... range is 1 999 Room no range is 01 63 01 32 e g 0101 device no range is 01 02 see diagram below Note The external and internal types cannot be used in mixed scenarios in the same apartment Switch Router Device ID 01 02 Block no 1 999 Room no 0101 6332 Master Home network Community network ...

Страница 92: ...Commissioning Product manual 2TMD041800D0002 92 Power lock settings On the IP actuator settings screen set output mode and unlock time ...

Страница 93: ...Commissioning Product manual 2TMD041800D0002 93 Relay lock settings On the IP actuator settings screen set Relay mode and unlock time ...

Страница 94: ...sioning Product manual 2TMD041800D0002 94 Report when unlock On the IP actuator settings screen if Report when unlock is enabled each unlock record from the IP actuator will be sent to the management software ...

Страница 95: ... 95 Exit button On the IP actuator settings screen set the lock type for the exit button Power lock or Relay lock Door status detection On the IP actuator settings screen tick the checkbox to enable the function Door open period range is 1 600 s ...

Страница 96: ...Firmware update The IP actuator must exit engineering mode before the firmware is upgraded On the Engineering settings screen click IP actuator settings Firmware update select IP actuator and the file from SD card then click OK to update the firmware ...

Страница 97: ...neering setting screen click Smart home settings to access the corresponding screen 1 Smart home mode KNX settings default On the Smart home settings screen click Read SD card and import the KNX settings from the file stored on the SD card The KNX screen will be displayed if successful ...

Страница 98: ...Commissioning Product manual 2TMD041800D0002 98 2 Smart home mode free home On the Smart home settings screen click System Access Point followed by the name ...

Страница 99: ...Commissioning Product manual 2TMD041800D0002 99 Enter the user name and password and click OK ...

Страница 100: ...Commissioning Product manual 2TMD041800D0002 100 The Home screen of free home is set on SysAP Please see the SysAP product manual for more details ...

Страница 101: ...details 4 Program button The address of default lock must be set before this function can be used Please see the Set the address of default lock chapter and the Program button settings chapter for more details 5 Mute Click this icon to mute the ringtone on this indoor station Press this icon and hold for 3 s to mute the ringtone of all the devices in the same apartment Please see the Mute chapter ...

Страница 102: ...ll guard unit chapter for more details 9 History Click this icon to view the history records Please see the History chapter for more details 10 Voice message Click this icon to view the voice messages Please see the Voice message chapter for more details 11 Call the lift Click this icon to call the lift to current floor Please see the Call the lift chapter for more details 12 Status bar Display th...

Страница 103: ... s 3 Click this icon to accept the call 4 Release the default lock Click this icon to release the default lock on the calling outdoor station 5 Program button Click this icon to release the subsidiary lock on the calling outdoor station It can be set to switch on the light Please see the Program button settings chapter for more details 6 Click this icon to mute the ringtone on this device 7 Click ...

Страница 104: ... to take a snapshot manually 10 Click this icon to record a video when the SD is inserted 11 Select the image of the outdoor station or the camera from the drop down list 12 Click or to adjust the volume 13 Click this icon to end the call 14 Click this icon to mute the volume ...

Страница 105: ...2 Display the the countdown in the last 9 s 3 Click this icon to accept the incoming call 4 Click this icon to mute the ringtone on this device 5 Click this icon to switch between full screen and normal screen 6 Click or to adjust the volume 7 Click this icon to end the call 8 Click this icon to mute the volume ...

Страница 106: ...from doorbell When the doorbell is pressed this device will display for 5 s on the status bar If the doorbell is associated with the camera this indoor station will display the image from the camera automatically Please see the Home monitor for more details ...

Страница 107: ...Operation Product manual 2TMD041800D0002 107 9 3 Intercom 9 3 1 Enter intercom page In standby mode click on the DES home screen to enter the corresponding screen ...

Страница 108: ... 2 Initiating an intercom call Home to home On the Intercom contacts screen click Favorite contacts select a contact then click to initiate an intercom call You can also click and enter the physical address logic address to initiate an intercom call ...

Страница 109: ...1800D0002 109 Room to room On the Intercom contacts screen click Indoor extension Click Group call to initiate a call to all indoor stations in the same apartment Click a room e g Extension01 to initiate a call to this indoor station ...

Страница 110: ...ist There are 2 ways to add a contact to the blacklist Option 1 On the Intercom contacts screen click to access the setting Click the contact then select Blocked from the drop down list Option 2 On the History screen select an intercom record then click on the right ...

Страница 111: ...tion Product manual 2TMD041800D0002 111 9 3 4 Restoring a contact from the blacklist On the Intercom contracts screen press to access the setting Click the contact then select Allowed from the drop down list ...

Страница 112: ...Operation Product manual 2TMD041800D0002 112 9 4 Surveillance 9 4 1 Surveillance from outdoor station In standby mode on the DES screen click to access the corresponding screen ...

Страница 113: ... on the monitored outdoor station It can be set to switch on the light Please see the Program button settings chapter for more details 6 Mute default or unmute the volume during surveillance 7 Click this icon to display the image of the next outdoor station or the next camera 8 Click here to switch between full screen and normal screen 9 Click this icon to take a snapshot 10 Click this icon to rec...

Страница 114: ...yed in the last 9 s 3 End the surveillance 4 Click this icon to display the image of the next outdoor station or the next camera 5 Click here to switch between full screen and normal screen 6 Click this icon to take a snapshot 7 Click this icon to record a video only when an SD is inserted 8 Select the image of the outdoor station or the camera from the drop down list ...

Страница 115: ...D041800D0002 115 9 5 Call guard unit Call guard unit must be enabled before this function can be used On the Engineering settings screen click Local settings set Call Guard unit to on Then set the address of the default guard unit ...

Страница 116: ...Operation Product manual 2TMD041800D0002 116 On the Door entry screen click to call the default guard unit ...

Страница 117: ...tion Product manual 2TMD041800D0002 117 9 6 History In standby mode click on the status bar to access the corresponding screen A maximum of 30 call records can be stored Highlighting indicates unread status ...

Страница 118: ...D041800D0002 118 Click to play the audio or video record on the pop up window when an SD card is inserted Click the picture to see details on the pop up window Click or to view the pictures a maximum of 3 pictures for each record ...

Страница 119: ...Operation Product manual 2TMD041800D0002 119 Click to enter the settings Click Delete All to delete the entire history record Click Copy to SD card to copy all snapshots to an inserted SD card ...

Страница 120: ...ce message Recording a new voice message In standby mode click on the status bar then click New voice message to access the corresponding screen Click to record a voice message click to play the voice message A maximum of 30 voice messages can be stored ...

Страница 121: ...02 121 Reading a voice message The indoor station will flash on the status bar if there is an unread message In standby mode click on the status bar then click Voice message to access the corresponding screen Click to play the voice message ...

Страница 122: ...for visitors and to record voice message from visitors Enable Absence message At least one voice message must exist before this function can be used Please see the Voice message chapter to add a voice message On the Voice message screen select a voice message and tick the checkbox Absence message to enable the function ...

Страница 123: ...Operation Product manual 2TMD041800D0002 123 Disable Absence message On the System settings screen click Door Entry System and untick Absence message ...

Страница 124: ... 124 9 9 Automatic unlock Unlock timer should be enabled before this function can be used On the System settings screen click Local settings then switch Unlock timer to on In standby mode click Unlock timer to access the corresponding screen ...

Страница 125: ... days of the week with the selected options shown with highlighting After setting the start time and end time click OK to save A maximum of 10 items is supported With this setting this device will enter auto unlock mode automatically and display on the status bar The lock will be released automatically 5 s later during an incoming call ...

Страница 126: ...ock On the extra screen click Unlock to access the settings Click and then click to add a new setting The lock type can be selected between Door lock and Actuator lock Select the lock location from the drop down list and enter the lock name then click OK to save ...

Страница 127: ... manual 2TMD041800D0002 127 Click to save and quit the setting A maximum of 16 items is supported In standby mode click the lock icon to release the lock the lock is released the lock is released Door lock Actuator lock ...

Страница 128: ... status bar and select Mute timer to access the corresponding screen Click and then click to add a new setting The system allows you to select the days of the week with the selected options shown with highlighting After setting the start time and end time click OK to save A maximum of 10 items is supported With this timer setting this indoor station will mute the ringtone automatically and display...

Страница 129: ...h on the status bar if there is an unread text message On the extra screen click Text message or click on the status bar to access the corresponding screen New text message On the Text message screen click enter the subject and content then click to send this message to the management software ...

Страница 130: ...the text messages come from management software means an unread text message Click to reply the text message On the Text message screen click INBOX then click to access the setting Click to mark all text message as read Click Delete all to delete all text messages Click to save and quit the setting ...

Страница 131: ...ration Product manual 2TMD041800D0002 131 Outbox On the Text message screen click OUTBOX to view the text messages sent to management software means an undelivered message Click to resend the text message ...

Страница 132: ...the SD card Audio and video files should be stored in the media folder and photos in the photo folder On the extra screen click Media player to access the corresponding screen 9 13 1 Multi media On the Media player screen click A V to play the audios or videos Media format supported mp3 wav mp4 avi The maximum video solution is 1920 x 1080 ...

Страница 133: ...a player screen click Image to play the pictures Click to play the pictures as a slideshow full screen by default Click to set the transition when displaying multiple photos Photo formats supported jpg png The maximum photo solution is 2048 x 1920 The maximum photo size is 3 M ...

Страница 134: ...800D0002 134 9 14 Call the lift Lift must be enabled before this function can be used On the Engineering settings screen click Local settings then switch Lift to on On the Door Entry screen click to call the lift to the current floor ...

Страница 135: ...Operation Product manual 2TMD041800D0002 135 will be displayed on the status bar if successful ...

Страница 136: ...oduct manual 2TMD041800D0002 136 9 15 Alarm This chapter is for the H82365 only Alarm must be enabled before this function can be used On the Engineering settings screen click Local settings then switch Alarm to on ...

Страница 137: ...er name to disarm the indoor station to avoid the alarm being triggered 3 Alarm duration Click or to set the alarm duration 4 Duress password Click Change duress password to change the password When the resident is under duress he can enter this password to disarm the indoor station At the same time an alarm message is sent to the guard unit and the management software The system default password ...

Страница 138: ...gram password This password is used to arm and disarm the indoor station The system default is 345678 Testing mode Click Start test mode to test that the zones are working properly Alarm type You can select Floor plan or Simple mode When Floor plan is selected the alarm icons will be displayed on a floor plan for more intuitive viewing Click to add a floor plan the SD card if an SD card is inserte...

Страница 139: ...al 2TMD041800D0002 139 Set alarm zone position On the Engineering settings screen click Advanced zone settings Alarm zone position Click anywhere to create an alarm zone Click Engineering settings to exit the current setting ...

Страница 140: ...Operation Product manual 2TMD041800D0002 140 Set alarm zone attribute On the Engineering settings screen click Advanced zone settings Alarm zone attribute ...

Страница 141: ...e is combined with a delay zone For example zone 1 delay zone zone 2 transfer delay zone If zone 2 is triggered first an alarm will be sounded and an alarm message will be sent to the guard unit and the management software If zone 1 is triggered a countdown will start Then when zone 2 is triggered within this countdown an alarm will be sounded and an alarm message will be sent to the guard unit an...

Страница 142: ...m screen click Arm all and enter the user password to arm the indoor station Note If the user password default is 123456 is used to arm the indoor station only that user password can be used to disarm it If the program password default is 345678 is used to arm the indoor station both the user password and the program password can be used to disarm it ...

Страница 143: ...Operation Product manual 2TMD041800D0002 143 If the alarm zones are armed the zone icons will turn red When an alarm zone is triggered the zone icon will turn orange ...

Страница 144: ...ation Product manual 2TMD041800D0002 144 Click Disarming then enter the password to disarm the indoor station Alarm history On the Alarm screen click to view the alarm history Click to play the alarm video ...

Страница 145: ...Operation Product manual 2TMD041800D0002 145 Alarm timer On the Alarm screen click then enter the user password to access the setting Then click and click to add a timer setting ...

Страница 146: ...l 2TMD041800D0002 146 A maximum of 10 items is supported With this timer setting the indoor station will arm automatically and will be displayed on the status bar Click Disarming and enter user password to disarm it manually ...

Страница 147: ...creen On the System settings screen click Display then click to access the corresponding screen The countdown 1 30 is displayed on the screen Any operations on the screen will be invalid This device will exit Clean screen mode if an incoming call is received ...

Страница 148: ...OTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause ...

Страница 149: ...ts are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this eq...

Страница 150: ...8236 product the network its system and interfaces against any kind of security breaches unauthorized access interference intrusion leakage and or theft of data or information ABB Ltd and its affiliates are not liable for damages and or losses related to such security breaches unauthorized access interference intrusion leakage and or theft of data or information Although ABB provides functionality...

Страница 151: ...client 5061 TCP To be used by sip server 5070 TCP To be used by sip server 50602 UDP To be used by sip server 7777 TCP UDP To be used for device management 7006 TCP To be used for connectivity detection when this feature is enabled 8001 TCP To be used for calling history report 8887 TCP To be used for firmware updating 10777 TLS Secure channel for device management 11778 TLS Secure channel for con...

Страница 152: ...verify the authentication and integrity of firmware If Internet services available device will connect to MyBuilding sever to get new firmware automatically but needs to be confirmed by end user every time A signature file will be used to verify the authentication and integrity of firmware 11 5 Backup Restore Some configurations of device can be exported to SD card for backup purpose and on later ...

Страница 153: ...ed specifications agreed to at the time of ordering apply to all orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained therein The document and its contents or excerpts thereof must not be reproduced transmitted or reused by third parties without prior written consent by ABB ...

Страница 154: ...anayi Bolgesi 2 Cadde No 16 Y Dudullu Istanbul T 90 216 528 2281 F 90 216 528 2945 ABB KSA Electrical Industries Co Ltd P O Box 325841 Riyadh 11371 T 966 1 1484 5600 F 966 1 1206 7609 ABB Thailand Ltd 161 1 SG Tower 1st 4th Floor Soi Mahadlekluang 3 Rajdamri Road Lumpini Pathumwan Bangkok 10330 Thailand T 66 2 6651 000 F 66 2 6651 043 ABB Russia Ltd 3121 Wiring Accessories 30 1 bld 2 Obrucheva str...

Страница 155: ...Error Use the Home tab to apply Überschrift 1 to the text that you want to appear here Product manual 2TMD041800D0002 155 Copyright 2019 ABB All rights reserved ...

Отзывы: