… Electromagnetic flowmeter WaterMaster – FEW31, FEW32 and FEW38

Product coding field number 1 … 5 6 7 … 9 10 11 12 13 14, 15 16 17 18 19 20 21 22 23 24 25 26 27

 Opt
ions

Flowmeter system – full bore, integral mount

FEW31

X XXX

X

X

X

X

XX

X

X

X

X

X

X

X

X

X

X

X

X

Flowmeter system – full bore, remote mount

FEW32

Full bore sensor only –  
for use with WaterMaster transmitter / remote

FEW38

Process connection type (refer to pages 23 to 24)

Flanges ASME B16.47 series B / B16.5 Class 150 
Flanges ASME B16.47 series B / B16.5 Class 300 
Flanges ASME B16.47 series A Class 150 
Flanges ASME B16.47 series A Class 300 
Flanges AWWA C207 Class B 
Flanges AWWA C207 Class D 
Flanges AWWA C207 Class E 
Flanges AWWA C207 Class F 
Flanges JIS 10K 
Flanges JIS 5K 
Flanges AS 4087 PN 16 
Flanges AS 2129 Table E 
Flanges AS 2129 Table D 
Flanges AS 4087 PN 35 
ISO 7005, DIN, EN 1092-1 PN6 
ISO 7005, DIN, EN 1092-1 PN10 
ISO 7005, DIN, EN 1092-1 PN16 
ISO 7005, DIN, EN 1092-1 PN25 
ISO 7005, DIN, EN 1092-1 PN40

A1 
A3 
B1 
B3 
C1 
C2 
C3 
C4 
J1 
J2 
E1 
E4 
E5 
E8 
S0 
S1 
S2 
S3 
S4

Process connection material

Carbon steel flanges 
Stainless steel flange


D

Usage certifications

Standard (without PED)

1

Calibration type

Class 2 calibration – standard accuracy 0.4 % 
Class 1 calibration – high accuracy 0.2 % 


B

Temperature range installation / ambient temperature range

Standard design/ –20 to 60 °C (–4 to 140 °F)

1

Nameplate

Adhesive

A

Signal cable length and type

Without signal cable 
5 m (15 ft.) cable  
10 m (30 ft.) cable  
20 m (60 ft.) cable  
30 m (100 ft.) cable  
50 m (165 ft.) cable  
80 m (260 ft.) cable  
100 m (325 ft.) cable 
150 m (490 ft.) cable 
Special length or cable type










9

Explosion protection certification*

General purpose (non-Ex design) 
FM Class 1 Div. 2 
usFMc Class 1 Div. 2 
ATEX / IECEx Zone 2, 21 & 22




M

Continued on next page…

Содержание WaterMaster

Страница 1: ... ABB MEASUREMENT ANALYTICS DATA SHEET WaterMaster Electromagnetic flowmeter ...

Страница 2: ...onfiguration eliminating the need to remove the cover smart key based functionality Easy Setup function VeriMaster in situ verification software option enables the customer to perform in situ verification of the flowmeter system Unparalleled service ability fault finding Help texts on the display minimized downtime with replaceable electronics cartridges MID and OIML R49 approved with R49 self che...

Страница 3: ...07 alarms and warnings are classified with the status of Maintenance Required Check Function Failure and Out of Specification Flow performance Utilizing its advanced filtering methods the WaterMaster improves accuracy even under difficult conditions WaterMaster has an operating flow range with 0 4 accuracy as standard 0 2 optional in both forward and reverse flow directions Easy and quick commissi...

Страница 4: ...es excavating to the underground pipe fitting the sensor cabling back to the transmitter and then backfilling the hole The WaterMaster family Overview of the WaterMaster A wide range of features and user benefits are built into WaterMaster as standard bi directional flow unique self calibrating transmitter patented for the ultimate in stability and repeatability OIML type continuous self checking ...

Страница 5: ...am ROM and RAM status double independent storage of totalizer values in both the sensor and transmitter non volatile memories display test The OIML R49 1 certificate of conformity is available from http www abb com product seitp330 b42ec2377d3293cdc12573de003db93b aspx WaterMaster is also approved under the EU Measuring Instruments Directive MID 2004 22 EC that covers putting into use water flowme...

Страница 6: ...imits DN100 4 in NB WaterMaster specification to OIML R49 Class 2 0 1 0 44 1 0 4 4 10 44 100 440 1000 4402 Error Typical meter performance 0 4 0 9 mm s whichever is the greater Around Q2 the performance is 0 7 mm s WaterMaster Class 2 specification OIML R49 Class 2 accuracy limits DN100 4 in NB Flowrate m3 h GPM Although OIML R49 does not define the flow accuracy below Q1 WaterMaster continues to ...

Страница 7: ...667 51 32 1000 80 50 700 20 000 16 000 1600 102 64 1600 160 100 750 20 000 16 000 1600 102 64 1600 160 100 30 in 750 20 000 16 000 1600 102 64 1600 160 100 800 20 000 16 000 1600 102 64 1600 160 100 900 31 250 25 000 2500 160 100 2500 250 156 1000 31 250 25 000 2500 160 100 2500 250 156 42 in 31 250 25 000 2500 160 100 2500 250 156 1100 31 250 25 000 2500 160 100 2500 250 156 1200 50 000 40 000 40...

Страница 8: ... 733 68 1650 346 726 277 381 27 738 1 775 1 110 27 738 2 773 1 733 77 1800 550 358 440 287 44 029 2 818 1 761 44 029 4 403 2 752 77 1950 550 358 440 287 44 029 2 818 1 761 44 029 4 403 2 752 78 2000 550 358 440 287 44 029 2 818 1 761 44 029 4 403 2 752 78 2000 550 358 440 287 44 029 2 818 1 761 44 029 4 403 2 752 84 2200 880 573 704 459 70 446 4 509 2 818 70 446 7 045 4 403 96 2400 880 573 704 459...

Страница 9: ...h Conductivity 20 µS cm 1 Transmitter mounting Integral not FEF or remote Electrical connections 20 mm glands 1 2 in NPT 20 mm armored glands Sensor cable ABB WaterMaster cable available in two forms standard and armored Maximum length 200 m 660 ft Suspended solids Suspended solids percentage of process medium should not exceed 6 of total volume Physical specification Wetted parts Electrode materi...

Страница 10: ...1 1 2 to 6 in NB FER DN40 to DN150 1 1 2 to 6 in NB Housing material Carbon steel FEV DN40 to 200 11 2 to 8 in NB FEW DN450 to 2400 18 to 96 in NB Plastic FEF DN250 to 600 10 to 24 in NB Aluminium FEW DN10 to 400 3 8 to 16 in NB Terminal box material Polycarbonate Cable gland material Plastic brass Paint specification Zinc based primed all sensors paint coat 70 µm thick RAL 9002 light grey in acco...

Страница 11: ...evented by internal switch combined with external security seals for MID applications Languages English French German Italian Spanish Polish Infrared service port USB adapter accessory USB 1 1 and 2 0 compatible Driver software for Windows 2000 XP 7 32 bit and Vista Housing material Powder coated aluminium with glass window Paint specification Paint coat 70 µm thick RAL 9002 light grey Transmitter...

Страница 12: ... connections Backplane Internal earth alternative PE Power cable Cable gland conduit entry Remote transmitter shown Sensor cable terminal connections and recommended cable lengths Inner wire For cathodically protected systems or if the transmitter enclosure does not have an earth screw connect the drain wire to terminal SCR See above for cable preparation requirements before connecting cable Drain...

Страница 13: ...nal earth screws Fuse supplier Fuse part number ABB B20411 Bussmann BK ETF 250 mA Wickmann 19372 K250mA Brown Blue Green Yellow AC power supply connections DC and low voltage AC power supply Power supply indicator LED DC Fuse F2 2 A Type T see table below for suppliers 4 mm2 10 AWG Copper wire DC or low voltage AC power via suitable isolator and fuse Transmitter label External earth screw Internal...

Страница 14: ...1 03 XX onwards and for all PROFIBUS software versions on MID meters all metrological related parameters are locked and inaccessible at the Service level Standard and Advanced user level parameters can still be modified via the HMI or bus Configuration DIP switches OFF ON SW3 SW2 SW1 DIP Switch functions SW1 Read only MID Protection SW2 future product SW3 Internal sensor memory Configuration DIP s...

Страница 15: ...ward flow output DO1 Counter Totalizer and or Reverse flow output DO2 Counter Totalizer Telemetry Electronic counters connections Alarm outputs Terminal connection IDs are HART PROFIBUS MODBUS variant dependent COM DO3 XX XX XX XX 42 41 51 61 52 62 COM DO1 DO2 DO3 DC supply Horn Alarm 1 Alarm 2 Bell and or Note Normal alarm logic output is from DO3 terminal 61 DO1 41 and DO2 51 can also be configu...

Страница 16: ...ransistor is 220 mA Current output 4 to 20 mA HART FEX100 variant Refer to IM WMP for HART Protocol communication details Current output 4 to 20 mA HART FEX100 variant RS485 communications PROFIBUS FEX100 DP and MODBUS FEX100 MB variants PROFIBUS MODBUS RS485 A1 B1 In A2 B2 Out Screen clamp Test point access Note A typical DVM probe can access fit the PCB s test holes IC IC O P1 O P2 COM 4 to 20 m...

Страница 17: ... structure for accessing device parameters configuring and operating the devices and diagnosing problems FDT Field Device Tool technology standardizes the communication and configuration interface between all field devices and host systems PROFIBUS DP protocol PROFIBUS is a manufacturer independent open Fieldbus standard for a wide range of applications in manufacturing process and building automa...

Страница 18: ... follows the specification for Modbus Over Serial Line V1 02 using 2 wire TIA EIA 485 RS485 physical layer Line terminator Pull down Pull up Balanced pair Slave 1 For example WaterMaster FEX100 MOD Slave n Common D1 D0 D D D R R R Line 5 V Up to 31 slaves Master Cable Properties The end to end length of the trunk cable must be limited The maximum length depends on the Baud rate the cable gauge cap...

Страница 19: ... potential should be identical to the potential of the metering fluid The fluid connection is made by installing 2 fluid contact rings for grounding Fluid contact rings Mounting The installation conditions shown below must be observed to achieve the best operational results The sensor tube must always be completely full The flow direction must correspond to the identification plate The device meas...

Страница 20: ...s ProcessMaster range Electrode axis Electrode axis should be horizontal if at all possible or no more than 45 from horizontal 45 Max Upstream and Downstream pipe sections The metering principle is tolerant of the flow profile Wherever possible do not install fittings for example manifolds valves directly in front of the flowmeter sensor Butterfly valves should be installed so that the valve plate...

Страница 21: ...CTROMAGNETIC FLOWMETER DS WM EN REV Y Transmitter dimensions Integral transmitter Dimensions in mm in 98 3 8 118 4 6 202 8 0 200 7 9 Remote transmitter Dimensions in mm in 98 3 8 152 6 0 71 2 8 R3 2 0 12 179 7 0 205 8 0 ...

Страница 22: ... in NB Dimensions in mm in G F E D L A C Remote transmitter terminal box manufactured before Q3 2014 Remote transmitter terminal box manufactured after Q3 2014 External earth ground connection 89 3 5 104 4 11 98 3 86 Ø104 4 11 Ø104 4 11 77 8 3 06 210 7 91 84 3 3 78 3 1 DN10 to 125 to 5 in NB FEW ...

Страница 23: ...N10 to 40 165 6 5 281 11 06 97 3 82 206 8 11 161 6 34 115 4 53 12 26 10 22 JIS5K 130 5 12 JIS10K 155 6 10 AS4087 PN16 150 5 91 AS4087 PN35 165 6 50 ASME B16 5 CL150 152 5 98 ASME B16 5 CL300 165 6 50 DN65 21 2 in PN10 to 40 185 7 28 292 11 50 108 4 25 217 8 54 172 6 77 104 4 09 13 29 11 24 JIS5K 155 6 10 JIS10K 175 6 89 AS4087 PN16 165 6 50 AS4087 PN35 185 7 28 ASME B16 5 CL150 178 7 01 ASME B16 5...

Страница 24: ... in NB Dimensions in mm in D C A L E F G 89 3 5 104 4 11 98 3 86 Ø104 4 11 Ø104 4 11 77 8 3 06 210 7 91 84 3 3 78 3 1 Remote transmitter terminal box manufactured before Q3 2014 Remote transmitter terminal box manufactured after Q3 2014 External earth ground connection DN150 to 400 6 to 16 in NB FEW ...

Страница 25: ...B16 5 CL300 445 17 52 105 231 103 227 ASME B16 5 CL150 405 15 94 70 154 68 150 DN300 12 in PN10 445 17 52 500 19 69 449 17 68 228 8 98 374 14 72 329 12 95 272 10 71 74 163 72 158 PN16 460 18 11 80 176 78 172 PN25 485 19 09 100 220 98 216 JIS5K 430 16 93 80 176 78 172 JIS10K 445 17 52 80 176 78 172 AS4087 PN16 455 17 91 80 176 78 172 AS4087 PN35 490 19 29 130 286 128 282 ASME B16 5 CL300 520 20 47 ...

Страница 26: ...5 00 250 551 248 547 PN25 670 26 38 N A 686 27 01 245 540 243 536 PN40 685 26 97 315 694 313 690 DN500 20 in PN10 670 26 38 N A 600 23 62 514 20 24 310 12 20 439 17 28 394 15 51 367 14 45 190 418 188 413 PN16 715 28 15 240 528 238 524 JIS5K 655 25 79 190 418 188 413 JIS10K 675 26 57 AS4087 PN16 705 27 76 290 638 288 634 AS4087 PN35 735 28 94 435 957 433 953 ASME B16 5 CL150 700 27 56 300 660 298 6...

Страница 27: ... 700 ASME CL300 SERIES B 990 38 98 748 1646 746 1641 DN800 32 in JIS 5K 995 39 17 800 31 49 1040 40 04 654 25 74 453 17 83 578 22 76 538 21 18 542 21 34 280 616 278 612 JIS 10K 1020 40 16 364 801 362 796 PN6 975 38 39 294 647 292 642 PN10 1015 39 96 406 893 404 889 PN16 1025 40 35 469 1032 467 1027 AWWA C207 CLASS B 1060 41 73 328 722 326 717 AWWA C207 CLASS D 1060 41 73 408 898 406 893 AS4087 PN1...

Страница 28: ... 41 610 1342 608 1338 AS2129 TABLE E 1255 49 41 833 1833 831 1028 PN25 1320 51 97 1207 2655 1205 2651 PN40 1360 53 54 1413 3109 1411 3104 AS4087 PN35 1275 50 20 1244 2737 1242 2732 ASME CL150 SERIES A 1290 50 79 1149 2528 1147 2523 ASME CL300 SERIES A 1240 48 82 1349 2968 1347 2963 ASME CL150 SERIES B 1175 46 26 738 1624 736 1619 ASME CL300 SERIES B 1275 50 20 1487 3271 1485 3267 DN1050 42 in AWWA...

Страница 29: ...264 1027 2259 JIS 10K 1795 70 67 1504 3309 1502 3304 ASME CL150 SERIES B 1725 67 91 2031 4468 2029 4464 AWWA C207 CLASS B 1854 72 99 1229 2704 1227 2699 AWWA C207 CLASS D 1854 72 99 1514 3331 1512 3326 AWWA C207 CLASS E 1854 72 99 2544 5597 2542 5592 ASME CL150 SERIES A 1855 73 03 3084 6785 3082 6780 ASME CL300 SERIES A 1810 71 26 3875 8525 3873 8521 ASME CL300 SERIES B 1880 74 02 4181 9198 4179 9...

Страница 30: ...EN1092 1 PN10 16 25 40 165 6 50 200 7 87 261 10 28 186 7 32 138 5 43 38 1 5 13 75 30 25 12 75 28 05 ASME B16 5 CLASS 150 DN80 3 in EN1092 1 PN10 16 25 40 200 7 87 200 7 87 280 11 04 205 5 8 09 157 5 6 2 61 2 4 17 2 37 84 16 2 35 64 ASME B16 5 CLASS 150 AS4087 PN16 21 AS2129 TABLE D E F DN100 4 in EN1092 1 PN10 16 25 40 225 8 86 250 9 84 300 5 11 83 225 5 8 88 177 5 6 98 70 2 76 19 3 42 5 18 3 40 3...

Страница 31: ... 7 28 AS2129 TABLE F 205 8 07 AS4087 PN21 205 8 07 DN100 4 in EN1092 1 PN10 PN16 220 8 66 250 9 84 320 12 60 63 75 2 51 245 9 65 196 8 7 75 70 2 76 19 42 18 40 ASME B16 5 CLASS 150 228 6 9 00 JIS 7 5K 238 9 37 JIS 10K 210 8 27 AS2129 TABLE C D 215 8 46 AS4087 PN14 PN16 215 8 46 AS2129 TABLE E 215 8 46 AS4087 PN21 230 9 06 AS2129 TABLE F 230 9 06 DN125 5 in EN1092 1 PN10 PN16 250 9 84 250 9 84 320 ...

Страница 32: ...D E F DN50 2 in EN1092 1 PN10 16 25 40 165 6 50 200 7 87 261 10 28 186 7 32 138 5 43 29 1 14 14 75 32 45 13 75 30 25 ASME B16 5 CLASS 150 DN80 3 in EN1092 1 PN10 16 25 40 200 7 87 200 7 87 280 11 04 205 5 8 09 157 5 6 2 47 1 85 21 2 46 64 20 2 44 4 ASME B16 5 CLASS 150 AS4087 PN16 21 AS2129 TABLE D E F DN100 4 in EN1092 1 PN10 16 25 40 225 8 86 250 9 84 300 5 11 83 225 5 8 88 177 5 6 98 64 2 52 27...

Страница 33: ... 9 00 JIS 7 5K 238 9 37 JIS 10K 210 8 27 AS2129 TABLE C D 215 8 46 AS4087 PN14 16 215 8 46 AS4087 PN21 230 9 06 DN125 5 in EN1092 1 PN10 16 250 9 84 250 9 84 320 12 60 63 75 2 51 245 9 65 197 7 76 64 2 52 27 59 25 55 EN1092 1 PN25 40 270 10 63 ASME B16 5 CLASS 150 254 10 00 JIS 10K 250 9 84 AS2129 TABLE C D 255 10 04 DN150 6 in EN1092 PN10 16 285 11 22 300 11 81 340 13 39 84 4 3 32 265 10 43 217 8...

Страница 34: ...34 WATERMASTER ELECTROMAGNETIC FLOWMETER DS WM EN REV Y Sensor dimensions FER DN350 to 600 14 to 24 in NB remote sensor X G C L A D Ø104 4 11 86 3 4 DN350 to 600 14 to 24 in NB FER remote sensor ...

Страница 35: ...1 PN10 615 24 21 700 27 56 537 21 14 285 11 22 467 18 39 390 15 35 480 18 90 394 15 52 160 352 EN1092 1 PN16 640 25 20 EN1092 1 PN25 670 26 38 EN1092 1 PN40 685 26 97 JIS 5K 605 23 82 JIS 10K 620 24 41 AS2129 TABLE C D E 640 25 20 AS2129 TABLE F 675 26 57 AS4087 PN14 PN16 640 25 20 AS4087 PN21 675 26 57 DN500 20 in EN1092 1 PN10 670 26 38 770 30 31 557 21 93 317 5 12 50 487 19 17 410 16 14 520 20 ...

Страница 36: ...STER ELECTROMAGNETIC FLOWMETER DS WM EN REV Y Sensor dimensions FEF DN250 to 600 10 to 24 in NB X G C L A D Ø104 4 11 86 3 4 Base Dimension C centre line to base of flowmeter body DN250 to 600 10 to 24 in NB FEF ...

Страница 37: ... 5 10 14 346 13 62 376 14 80 350 13 78 100 220 ASME B16 5 CLASS 300 585 23 03 570 22 44 EN1092 1 PN10 505 19 88 550 21 65 EN1092 1 PN16 520 20 47 550 21 65 EN1092 1 PN25 555 21 85 570 22 44 EN1092 1 PN40 580 22 83 570 22 44 JIS 5K 480 18 90 550 21 65 JIS 7 5K 530 20 87 550 21 65 JIS 10K 490 19 29 550 21 65 AS4087 PN14 PN16 525 20 67 550 21 65 AS2129 TABLE C D E 525 20 67 550 21 65 AS4087 PN21 550 ...

Страница 38: ...STER ELECTROMAGNETIC FLOWMETER DS WM EN REV Y Sensor dimensions FEF DN250 to 600 10 to 24 in NB X G C L A D Ø104 4 11 86 3 4 Base Dimension C centre line to base of flowmeter body DN250 to 600 10 to 24 in NB FEF ...

Страница 39: ... 520 20 47 500 19 69 217 455 ASME B16 5 CLASS 300 775 30 51 EN1092 1 PN10 670 26 38 EN1092 1 PN16 715 28 15 EN1092 1 PN25 730 28 74 EN1092 1 PN40 755 29 72 JIS 5K 655 25 79 JIS 7 5K 706 27 80 JIS 10K 675 26 57 AS4087 PN 14 PN16 705 27 76 AS2129 TABLE C D E 705 27 76 AS4087 PN21 735 28 94 AS2129 TABLE F 735 28 94 AS4087 PN35 735 28 94 AS2129 TABLE H 735 28 94 DN600 24 in ASME B16 5 CLASS 150 815 32...

Страница 40: ...3 4 9 Process connection type refer to pages 22 and 23 ASME B16 5 B class 150 ASME B16 5 B class 300 ISO EN PN40 DIN PN40 Other A1 A3 S4 D4 Z9 Process connection material Carbon steel flanges DN20 to 32 3 4 to 11 4 in NB Stainless steel flange 1 4571 316 Ti DN10 to 15 3 8 to 1 2 in NB Other B D Z Usage certifications Standard without PED Other 1 9 Calibration type Class 2 calibration standard accu...

Страница 41: ...ithout 100 to 230 V AC 50 Hz 24 V AC or 24 V DC 50 Hz 100 to 230 V AC 60 Hz 24 V AC or 24 V DC 60 Hz 0 1 2 3 4 Input and output signal type HART 20 mA pulse contact output PROFIBUS DP RS485 physical layer pulse contact output general purpose design only MODBUS RTU RS485 physical layer pulse contact output general purpose design only Without A G M Y Configuration type diagnostics type Not required ...

Страница 42: ...aterial Stainless steel 316 Hastelloy C 22 Super austenitic steel S C U Grounding accessories Standard One potential equalizing ring stainless steel Two potential equalizing rings stainless steel 1 3 4 Process connection type refer to pages 30 and 31 Flanges ASME B16 5 class 150 Flanges AS 4087 PN21 DN50 2 in NB Flanges AS 4087 PN16 DN50 2 in NB Flanges AS 4087 PN14 Flanges AS 2129 Table F Flanges...

Страница 43: ...lass 1 Div 2 usFMc Class 1 Div 2 ATEX IECEx Zone 2 21 22 A G P M Protection class transmitter protection class sensor IP67 NEMA 4X IP67 NEMA 4X integral IP67 NEMA 4X IP68 NEMA 6P cable not fitted and not potted IP67 NEMA 4X IP68 NEMA 6P cable fitted and potted 1 2 3 Cable conduits M20 x 1 5 plastic NPT 1 2 in blanked when cable not fitted M20 SWA armored M20 SWA sensor M20 x 1 5 plastic power outp...

Страница 44: ... for use with WaterMaster transmitter remote FEV18 Options Accessories Configuration lead AC Documentation language German Italian Spanish French English M1 M2 M3 M4 M5 default Chinese Swedish Finnish Portuguese Danish Norwegian M6 M7 M8 MA MF MN Other usage certifications Measuring Instruments Directive MID OIML R49 Calibration CM1 CM2 Verification type Without fingerprint VeriMaster V0 V3 Potabl...

Страница 45: ...ne potential equalizing ring stainless steel Two potential equalizing rings stainless steel Others 1 3 4 9 Process connection type refer to pages 36 to 37 Flanges ASME B16 5 class 150 Flanges ASME B16 5 class 300 Flanges AWWA C207 class B Flanges AWWA C207 class D Flanges AS 4087 PN21 Flanges AS 4087 PN16 Flanges AS 4087 PN14 Flanges AS 2129 Table F Flanges AS 2129 Table E Flanges AS 2129 Table D ...

Страница 46: ... 1 5 plastic NPT 1 2 in blanked when cable not fitted M20 SWA armored M20 SWA sensor M20 x 1 5 plastic power output Without A B D F Y Power supply Without 100 to 230 V AC 50 Hz 24 V AC or 24 V DC 50 Hz 100 to 230 V AC 60 Hz 24 V AC or 24 V DC 60 Hz 0 1 2 3 4 Input and output signal type HART 20 mA pulse contact output PROFIBUS DP RS485 physical layer pulse contact output MODBUS RTU RS485 physical ...

Страница 47: ...N450 18 in DN500 20 in DN600 24 in DN700 28 in DN750 30 in DN800 32 in DN900 36 in DN1000 40 in DN1050 42 in DN1100 44 in DN1200 48 in DN1350 54 in DN1400 56 in DN1500 60 in DN1600 64 in DN1650 66 in DN1800 72 in DN1950 78 in DN2000 80 in DN2100 84 in DN2200 88 in DN2400 96 in Others 010 015 020 025 032 040 050 065 080 100 125 150 200 250 300 350 400 450 500 600 700 750 800 900 001 051 101 201 351...

Страница 48: ...7 PN 16 Flanges AS 2129 Table E Flanges AS 2129 Table D Flanges AS 4087 PN 35 ISO 7005 DIN EN 1092 1 PN6 ISO 7005 DIN EN 1092 1 PN10 ISO 7005 DIN EN 1092 1 PN16 ISO 7005 DIN EN 1092 1 PN25 ISO 7005 DIN EN 1092 1 PN40 A1 A3 B1 B3 C1 C2 C3 C4 J1 J2 E1 E4 E5 E8 S0 S1 S2 S3 S4 Process connection material Carbon steel flanges Stainless steel flange B D Usage certifications Standard without PED 1 Calibr...

Страница 49: ...RS485 physical layer pulse contact output MODBUS RTU RS485 physical layer pulse contact output Without A G M Y Configuration type diagnostics type Not required Factory default Standard 0 1 Options Accessories Configuration lead AC Documentation language German Italian Spanish French English M1 M2 M3 M4 M5 default Chinese Swedish Finnish Portuguese Danish Norwegian M6 M7 M8 MA MF MN Lay length ISO ...

Страница 50: ...in NB K Electrode design Standard 1 Measuring electrodes material Stainless steel 316 Super austenitic steel 1 4529 S U Grounding accessories 1 x Stainless steel equalizing ring 2 x Stainless steel equalizing rings 3 4 Process connection type refer to pages 30 and 30 Flanges ANSI ASME B16 5 16 47 series B Class 150 Flanges AWWA C207 Class E Flanges JIS 7 5K Flanges JIS 10K Flanges AS 4087 PN 21 Fl...

Страница 51: ...8 NEMA 6P cable not fitted and not potted IP67 NEMA 4X IP68 NEMA 6P cable fitted and potted 2 3 Cable conduits M20 x 1 5 NPT 1 2 in blanked when cable not fitted M20 SWA armored FEV121 and FEV181 only M20 SWA sensor output and power connector FEV121 and FEV181 only A B D F Power supply Without FEV18 only 100 230 V AC 50 Hz 24 V AC or 24 V DC 50 Hz 100 230 V AC 60 Hz 24 V AC or 24 V DC 60 Hz 0 1 2 ...

Страница 52: ...P67 NEMA 4X 1 Cable conduits M20 x 1 5 plastic NPT 1 2 in blanked when cable not fitted M20 SWA armored M20 SWA sensor M20 x 1 5 plastic power output Without A B D F Y Power supply 100 to 230 V AC 24 V AC or 24 V DC 1 2 Input and output signal type HART 20 mA pulse contact output PROFIBUS DP RS485 physical layer pulse contact output MODBUS RTU RS485 physical layer pulse contact output A G M Config...

Страница 53: ...60 ft 100 m 325 ft 150 m 490 ft 500 m 1650 ft STT4500 05 STT4500 10 STT4500 20 STT4500 30 STT4500 50 STT4500 80 STT4500 100 STT4500 150 STT4500 500 Armored signal cable for remote WaterMaster transmitter 5 m 15 ft 10 m 30 ft 20 m 60 ft 30 m 100 ft 50 m 165 ft 80 m 260 ft 100 m 325 ft 150 m 490 ft 500 m 1650 ft STT4501 05 STT4501 10 STT4501 20 STT4501 30 STT4501 50 STT4501 80 STT4501 100 STT4501 15...

Страница 54: ...54 WATERMASTER ELECTROMAGNETIC FLOWMETER DS WM EN REV Y Notes Sales Service Software ...

Страница 55: ...55 WATERMASTER ELECTROMAGNETIC FLOWMETER DS WM EN REV Y ...

Страница 56: ... 0 21 6105 6992 Mail china instrumentation cn abb com We reserve the right to make technical changes or modify the contents of this document without prior notice With regard to purchase orders the agreed particulars shall prevail ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document We reserve all rights in this document and in the ...

Отзывы: